The Danfoss 131N0193 is a three-phase HVAC drive from the VLT FC 101 HVAC Basic Drives series with a power rating of 15 kW and 20 horsepower. It operates at a mains voltage of 380 to 480 VAC and features an alpha numeric LCP display. The drive has an IP54 protection level and is equipped with an RFI filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131N0193 is an AC variable frequency drive supplied by Danfoss in the VLT FC 101 HVAC Basic Drives series. It converts fixed-frequency mains power into a variable-frequency output, allowing facility controllers to adjust induction motor speed according to real-time airflow or water-flow demand. This capability supports efficient operation in ventilation systems, chillers, pumps, and other motor-driven equipment used in commercial and industrial facilities. Matching motor speed to the load can reduce electrical consumption and limit unnecessary mechanical wear compared with continuous fixed-speed operation.

The inverter delivers 15 kW of continuous shaft power, which is equivalent to 20 HP and suits midrange air-moving and pumping equipment. It operates from a 380–480 VAC supply using three-phase power, allowing connection to common building and industrial feeders. This input range is compatible with IEC 400 V utility systems commonly used for HVAC machinery. The balanced three-line input supports efficient power conversion without requiring a neutral conductor for the motor power circuit. The enclosure provides IP54 protection without a Type 12 rating, preventing harmful dust accumulation and protecting internal components against splashing water. This enclosure allows the drive to be installed on mechanical skids or in mechanical rooms where airborne particles and incidental moisture may be present.

Motor conductors pass through standard cable entries, and the pre-machined gland plates associated with Adaptation A simplify cable routing into the enclosure. The drive includes no brake chopper, so applications that require controlled dissipation of regenerated energy must use a suitable external arrangement. An integrated RFI filter reduces conducted electrical interference that could otherwise affect nearby equipment or the incoming power network. Operator interaction is handled by an alphanumeric local control panel, which displays operating codes, parameter values, status information, and set points without a graphical interface. The printed circuit boards are not coated, so the drive should be installed in a noncondensing location that does not expose the electronics to corrosive moisture or airborne contaminants. Its standard control configuration operates without auxiliary option modules, keeping the field wiring focused on the mains supply, motor connections, and required control signals.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
Horse Power
20 HP
LCP
Alpha Numeric LCP
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Phase Rating
Three phase
Power Rating
15 KW
Product Group
VLT HVAC Drive
Protection Level
IP54 (not TYPE 12)
RFI Filter
RFI Filter
Series
101

Frequently Asked Questions about 131N0193:

Q: What is the horsepower rating of the 131N0193 VLT FC 101 drive?

A: The 131N0193 is rated for 20 horsepower, supporting demanding HVAC applications.

Q: What mains voltage and phase are required for the 131N0193 drive?

A: This model operates on a three-phase 380 to 480 VAC mains voltage input.

Q: What is the protection level of the 131N0193 VLT FC 101 drive?

A: The drive features an IP54 protection level, offering resistance against dust and water spray.

Q: What local control panel is supplied with the 131N0193 HVAC drive?

A: An alpha numeric LCP is included with the 131N0193 for user interface and control.

Q: Does the 131N0193 VLT FC 101 drive include an RFI filter?

A: The 131N0193 is equipped with an RFI filter for electromagnetic interference suppression.


Internal Product Review

  • ‘‘The 131N0193 is a Danfoss VLT FC 101 HVAC Basic Drive engineered for stable HVAC duty on 380 - 480 VAC three-phase systems. Technical appeal comes from the 20 HP and 15 kW rating, which suits a wide range of fan and pump applications with confident capacity. The integrated RFI filter and alphanumeric LCP support cleaner operation and straightforward commissioning, making 131N0193 a strong HVAC drive selection.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo