The Danfoss 134U6982 is part of the VLT FCD 302 Decentral Drives series and has a power rating of 0.37 kW, or 0.5 HP. It features a Profinet A option, service switch on the motor side, and comes with flat brackets and a standard black IP66/NEMA4X enclosure. This model supports 380-480VAC three-phase mains voltage and includes an RFI Class A1/C2 filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 134U6982 decentralized frequency converter is produced by Danfoss for the VLT FCD 302 Decentral Drives series. Designed for direct mounting on machinery, it provides variable-speed control for a three-phase induction motor without requiring installation inside a control cabinet. The unit belongs to the VLT Decentral Drive FCD product group and has a complete, small, stand-alone configuration. It can function as both an inverter and a local control node in automated conveyors, mixers, packaging lines, and other distributed motion applications. Locating the converter near the motor can reduce long motor-cable runs and simplify the physical layout of decentralized equipment.

The drive provides a mechanical output of 0.37 kW, which is equivalent to 0.5 HP, and operates from a three-phase mains supply ranging from 380 to 480 VAC. Its standard black enclosure has an IP66/NEMA 4X rating, providing protection against dust, water jets, and outdoor exposure. Communication is handled through the Profinet A-option, which supports cyclic process-data exchange and remote diagnostics over an Ethernet network. A front display connector allows local access for parameter entry and operating adjustments. The converter does not have an integral brake, so applications that require dynamic braking must use an appropriate external arrangement. Mains, motor, and sensor plugs are not included, allowing the required cable terminations to be selected for the installation.

The converter uses flat mounting brackets that position it parallel to the machine surface and provide a stable attachment point. Cable glands fit into metric threads, supporting commonly available sealing hardware and straightforward cable routing. Electromagnetic emissions are reduced by an integrated Class A1/C2 RFI filter, which helps limit conducted interference near other control equipment and instrumentation. A service switch on the motor side disconnects output power locally when the connected motor must be isolated. The fieldbus plug position is available for a compatible connector when the network layout requires one. The internal VLT Series 302 code identifies its platform within the broader decentralized drive range.

A Option
Profinet
B Option
No B option
Brackets
Flat brackets
Brake
No brake
D Option
No option
Display
With display connector
Enclosure
Standard Black IP66/NEMA4X
Fieldbus Plug
No fieldbus plug
Hardware Configuration
Compl. small stand alone
Horse Power
0.5 HP
Mains Plug
No mains plug
Mains Voltage
380-480VAC (Three phased)
Motor Plug
No Motor Plug
Power Rating
0.37 kW
Product Group
VLT Decentral Drive FCD
Reserved
Reserved
Reserved for SW
Reserved for SW
RFI Filter
RFI Class A1/C2
Sensor Plug
No sensor plugs
Switch Option
Service switch motor side
Threads
Metric threads
VLT Series
302

Frequently Asked Questions about 134U6982:

Q: What fieldbus or communication option does the 134U6982 support?

A: The Danfoss 134U6982 features a Profinet communication option for network connectivity.

Q: What is the horsepower rating of the Danfoss 134U6982?

A: This model provides a 0.5 horsepower rating, suitable for driving small motors.

Q: What type of enclosure does the 134U6982 decentralized drive have?

A: The enclosure is rated IP66/NEMA4X in standard black, offering protection against dust and water.

Q: What is the mains voltage requirement for the 134U6982?

A: This unit operates on a three-phase mains voltage range of 380-480VAC.

Q: What type of threads are used in the Danfoss 134U6982?

A: Metric threads are used on the Danfoss 134U6982 for installation and connectivity.


Internal Product Review

  • ‘‘The 134U6982 is a Danfoss VLT FCD 302 decentral drive configured for 0.37 kW output and 380-480 VAC three-phase supply. Profinet communication and an RFI Class A1/C2 filter support clean network integration and stable operation in distributed drive layouts. IP66/NEMA 4X enclosure protection and a motor-side service switch make the package especially well suited for demanding decentralized installations.’’