134F4072 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: FCD302PXXXT4W66H1XTEMXCXXXXXAXBXXXXXXDX
The Danfoss 134F4072 is part of the VLT FCD 302 Decentral Drives series and features a standard white IP66/NEMA4X enclosure with flat brackets and metric threads. Designed for three-phase mains voltage from 380 to 480VAC, it includes an RFI Class A1/C2 filter and a display connector.
Internal Product Review
The 134F4072 is a Danfoss VLT FCD 302 Decentral Drive installation box featuring a standard white IP66/NEMA4X enclosure for excellent protection in demanding environments. Metric threads and flat brackets provide straightforward installation and compatibility with various setups. With an integrated display connector and RFI Class A1/C2 filtering, this unit stands out for both ease of use and reliable EMC performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 134F4072 installation box is produced by Danfoss as part of the VLT FCD 302 Decentral Drives series. It serves as the decentralized interface that lets a VLT drive mount directly on equipment rather than inside a cabinet, supporting local motor speed control in conveyor, pump, and fan applications within industrial automation. By relocating power and signal termination points closer to the load, the unit helps shorten wiring runs and simplifies setup on production floors. This layout places the connection point near the machine, which can make decentralized drive installation more practical where cabinet space is limited.
The installation box fixes to machinery with flat brackets, while its cable entries use metric threads for standard gland fittings. It draws power from a three-phase 380-480 VAC supply, and internal terminals distribute line, motor, and control conductors to the attached VLT motor unit. This arrangement keeps external cabling organized around the drive assembly and supports direct machine mounting. The white housing is rated IP66/NEMA4X, so it resists high-pressure washdown and airborne particles in food or packaging zones. An integrated RFI Class A1/C2 filter reduces conducted noise when long shielded motor leads are used.
Drive-side hardware is intentionally limited; the unit has no brake circuitry and no fieldbus option. It is listed as Installation Box Only because the control inverter is located elsewhere in the VLT Decentral Drive FCD architecture. The incoming power connection has no mains plug, and the outgoing motor feeder is also supplied without a motor plug. Signal interfaces likewise omit sensor plugs and the fieldbus plug, while a display connector is provided for service tools. Reserved and Reserved for SW are retained as internal software placeholders rather than user-facing functions.