4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

132L2752 Danfoss

Ask for Availability

Current response time:
4 Minutes 55 Seconds

Preparing your secure checkout page...

The Danfoss 132L2752 is part of the VLT FCD 302 Decentral Drives series and supports a three-phase mains voltage of 380 to 480 VAC. This drive delivers a power rating of 2.2 kW or 3.0 HP and includes a Profibus DP communication option. It features an IP66/NEMA 4X standard black enclosure with an RFI Class A1/C2 filter and a 24VDC backup input.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 132L2752 decentralized AC motor drive is manufactured by Danfoss as part of the VLT FCD 302 Decentral Drives series. Mounted directly on the machine instead of inside a control cabinet, it changes output frequency and voltage to control induction motors on conveyors, pumps, and material-handling stations. Locating the electronics at the point of use removes long shielded motor cables and frees panel space. Because the drive is mounted near the load, the installation can keep motor leads shorter and route power more directly along the machine frame. The stand-alone design keeps communication and power components together in one unit.

The drive’s communication slot is configured for Profibus DP, enabling cyclic control and diagnostic data exchange without extra gateways. It accepts a three-phase supply of 380-480 VAC and delivers 2.2 kW, equal to 3.0 HP, to the motor. A standard black IP66/NEMA 4X housing protects the electronics from dust and washdown, so a control cabinet is unnecessary. A display connector provides local parameter entry, and the B slot is empty because no auxiliary module is included. Brackets are omitted, and the fieldbus, line power, and motor plugs are not installed, so wiring passes through fixed glands. This arrangement supports decentralized layouts where the drive operates outside the main cabinet and still provides direct access for local setup. The unit is supplied in the complete large stand-alone configuration.

For power-loss events, the D slot carries a 24 VDC backup input that keeps the control board active until line power returns. This helps preserve communication and control functions during brief interruptions, which is useful when the drive must recover without a full reset. Conducted emissions are limited by the integrated RFI Class A1/C2 filter, reducing the need for external line chokes. All threaded openings use metric threads, and no mechanical brake, sensor plugs, or manual switch option is installed. Two identifiers are reserved for future additions. The product belongs to the 302 generation of VLT drives and is listed under the VLT Decentral Drive FCD group.

A Option
Profibus DP
B Option
No B option
Brackets
No brackets
Brake
No brake
D Option
24VDC back-up input
Display
With display connector
Enclosure
Standard Black IP66/NEMA4X
Fieldbus Plug
No fieldbus plug
Hardware Configuration
Compl. large stand alone
Horse Power
3.0 HP
Mains Plug
No mains plug
Mains Voltage
380-480VAC (Three phased)
Motor Plug
No Motor Plug
Power Rating
2.2 KW
Product Group
VLT Decentral Drive FCD
Reserved
Reserved
Reserved for SW
Reserved for SW
RFI Filter
RFI Class A1/C2
Sensor Plug
No sensor plugs
Switch Option
No switch option
Threads
Metric threads
VLT Series
302

Frequently Asked Questions about 132L2752:

Q: What fieldbus communication is available on the 132L2752 drive?

A: The 132L2752 drive is equipped with Profibus DP as its A Option for fieldbus communication.

Q: What mains voltage does the Danfoss 132L2752 operate with?

A: This model supports three-phase mains voltage ranging from 380 to 480 VAC.

Q: What type of enclosure protection does the 132L2752 feature?

A: The enclosure is rated Standard Black IP66/NEMA4X, providing protection against dust and powerful water jets.

Q: What is the power and horsepower rating for the 132L2752 drive?

A: The VLT FCD 302 Decentral Drives 132L2752 is rated for 3.0 HP (2.2 KW) output.

Q: Does the Danfoss 132L2752 include a display connector?

A: This drive comes with a display connector included for monitoring and configuration.


Internal Product Review

  • ‘‘The 132L2752 from the VLT FCD 302 Decentral Drives series by Danfoss is a versatile drive unit with a 3.0 HP power rating and a 24VDC back-up input for enhanced reliability. Its standard black enclosure meets IP66/NEMA4X standards, making it ideal for demanding industrial environments. Profibus DP connectivity and RFI Class A1/C2 filtering further contribute to stable and efficient operation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo