FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX is part of the VLT FC 302 Automation Drives series and has a rated power of 1.1 kW. This drive offers 2 analog inputs, 2 digital outputs, and supports a maximum shielded cable length of 150 meters and unshielded cable up to 300 meters. It features an IP20 enclosure rated as size A2 and operates on three supply phases.
Internal Product Review
The FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 302 automation drive configured for 1.1 kW output with 3-phase supply. IP20 enclosure protection and Class A2 EMC emission performance support clean panel integration and reliable operation in controlled industrial settings. A maximum pulse frequency of 110 kHz stands out as a strong spec for smooth and precise drive response.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX is an AC variable-frequency drive produced by Danfoss as part of the VLT FC 302 Automation Drives series. It converts fixed-frequency three-phase power into a regulated output that lets controllers vary motor speed and torque in conveyors, pumps, and ventilation equipment. By combining motor control, basic safety, and EMC features inside a compact IP20 chassis, the unit helps reduce panel space and replace mechanical throttling devices while maintaining precise, energy-efficient process control.
The drive supplies up to 1.1 kW of continuous output and accepts a three-phase mains connection, allowing direct connection to standard 400–480 V industrial networks. Carrier modulation can reach 110 kHz, allowing a balance between acoustic noise and switching losses. Two analog inputs, two digital outputs, and six programmable digital inputs are provided; each input channel tolerates up to 28 V DC. Field wiring is accommodated by spring clamps rated for conductors no larger than 1.5 mm². The design omits an internal brake chopper and is supplied without a C1 filter or specialized mains option, relying on external hardware when dynamic braking or stricter emission limits are required. The printed circuit board assemblies are uncoated, and the unit is supplied without a local control panel.
An IP20 enclosure with an A2 frame size protects live parts while remaining slim enough for crowded cabinets. Standard cable entries are prepunched in the base plate, and motor leads can be run up to 150 m when shielded or 300 m when unshielded without exceeding Danfoss guidelines. EMC Category 3 and Emission Class A2 ratings support use in typical factory settings. The Safe Torque Off circuit draws only 50 mA rms at 24 V to cut power to the IGBTs during emergency stops. Because the circuit boards lack conformal coating, the drive should be mounted in a clean, dry location.