4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX Danfoss

Available, Ships in 1-2 weeks
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 302 automation drive configured for 1.1 kW output with 3-phase supply. IP20 enclosure protection and Class A2 EMC emission performance support clean panel integration and reliable operation in controlled industrial settings. A maximum pulse frequency of 110 kHz stands out as a strong spec for smooth and precise drive response.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX is an AC variable-frequency drive produced by Danfoss as part of the VLT FC 302 Automation Drives series. It converts fixed-frequency three-phase power into a regulated output that lets controllers vary motor speed and torque in conveyors, pumps, and ventilation equipment. By combining motor control, basic safety, and EMC features inside a compact IP20 chassis, the unit helps reduce panel space and replace mechanical throttling devices while maintaining precise, energy-efficient process control.

The drive supplies up to 1.1 kW of continuous output and accepts a three-phase mains connection, allowing direct connection to standard 400–480 V industrial networks. Carrier modulation can reach 110 kHz, allowing a balance between acoustic noise and switching losses. Two analog inputs, two digital outputs, and six programmable digital inputs are provided; each input channel tolerates up to 28 V DC. Field wiring is accommodated by spring clamps rated for conductors no larger than 1.5 mm². The design omits an internal brake chopper and is supplied without a C1 filter or specialized mains option, relying on external hardware when dynamic braking or stricter emission limits are required. The printed circuit board assemblies are uncoated, and the unit is supplied without a local control panel.

An IP20 enclosure with an A2 frame size protects live parts while remaining slim enough for crowded cabinets. Standard cable entries are prepunched in the base plate, and motor leads can be run up to 150 m when shielded or 300 m when unshielded without exceeding Danfoss guidelines. EMC Category 3 and Emission Class A2 ratings support use in typical factory settings. The Safe Torque Off circuit draws only 50 mA rms at 24 V to cut power to the IGBTs during emergency stops. Because the circuit boards lack conformal coating, the drive should be mounted in a clean, dry location.

Analog Inputs
2
Brake Chopper
None
C1 Option
No C1 Option
Cable Entries
Standard
Control Terminal Max
1.5 mm²
Digital Input Max
28 V DC
Digital Outputs
2
Emc Category
Category 3
Emc Emission Class
Class A2
Enclosure Rating
IP20
Enclosure Size
A2
LCP
No LCP
Mains Option
No Mains Option
Max Shielded Cable
150 m
Max Unshielded Cable
300 m
PCB Coating
Not Coated
Product Group
VLT AutomationDrive FC
Pulse Frequency Max
110 kHz
Rated Power
1.1 kW
Sto Current At 24 V
50 mA rms
Supply Phases
3

Frequently Asked Questions about FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX:

Q: What is the rated power output of the FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX drive?

A: The FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX has a rated power of 1.1 kW.

Q: What kind of enclosure protection does the FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX offer?

A: This model features an IP20 enclosure rating, meaning it provides protection against solid objects greater than 12.5 mm but does not have water ingress protection.

Q: How many analog inputs and digital outputs are available on the FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX?

A: The drive supports up to 2 analog inputs and 2 digital outputs for versatile control and monitoring.

Q: What is the maximum allowed unshielded cable length for the FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX?

A: This unit can handle a maximum unshielded cable length of 300 meters.

Q: How many supply phases does the FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX require?

A: The FC302P1K1T5E20H2XGXXXXSXXXXAXBXCXXXXDX operates on 3 supply phases.