The Danfoss FC-302PK75T5E is part of the VLT FC 302 Automation Drives series and supports a power rating of 0.75 kW or 1.0 HP. It operates on three phase power at 380 to 500 VAC and can output voltages up to the full supply voltage. The drive achieves a displacement power factor greater than 0.98 and offers a starting torque of 160 percent for 60 seconds.
Internal Product Review
The FC-302PK75T5E is a Danfoss VLT FC 302 automation drive engineered for three-phase 380 to 500 VAC systems. Fast torque response, with 1 ms flux torque rise time and 160% starting torque for 60 s, supports stable acceleration and precise load handling. The combination of IE2 efficiency and 590 Hz maximum output frequency makes the drive a strong choice for demanding automation service.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-302PK75T5E is an AC variable-frequency drive manufactured by Danfoss within the VLT FC 302 Automation Drives series. It receives three-phase utility power and synthesizes a variable output that lets control systems match motor speed to real-time load demands in conveyors, pumps, and fans. A digital signal processor handles vector control routines, while built-in diagnostics supervise DC-link voltage, temperature, and switching events so the drive can be mounted in distributed panels without additional supervisory hardware.
The input section accepts a mains range of 380–500 VAC, allowing direct connection to common industrial feeders. At full load, the inverter delivers 0.75 kW of rated power, which is equivalent to 1.0 HP at the motor terminals. Frequency modulation extends to a maximum of 590 Hz, supporting high-speed spindle or blower applications that need output well above the line frequency. For demanding starts, the control algorithm supplies 160% for 60 s of rated torque so heavy inertial loads can accelerate without oversizing the motor. The drive has a flux-torque rise time of 1 ms and a VVC+ torque rise time of 10 ms, indicating the response intervals between command changes and mechanical output.
The power stage is designed for three-phase power distribution and maintains a displacement power factor above 0.98, while the true power factor remains at or above 0.9 to minimize reactive draw on the supply network. During deceleration, the brake chopper activates at 810 V DC. Protective logic issues a high-voltage warning at 840 V DC, followed by an overvoltage alarm at 855 V DC to protect the DC-bus components. The drive meets the IE2 efficiency classification, and its motor output voltage can reach 100% of the supply voltage. It also limits power-up cycling to two starts per minute to protect the semiconductor devices and attached machinery.