Internal Product Review

The FC-302PK75T is a Danfoss VLT FC 302 automation drive rated at 0.75 kW for three-phase power applications. Strong control performance stands out, with 160% starting torque for 60 s and a 590 Hz maximum output frequency supporting demanding operating profiles. IE2 efficiency and 45 °C full-current ambient capability make the unit a well-balanced choice for dependable automation service.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-302PK75T is an AC variable frequency drive manufactured by Danfoss for the VLT FC 302 Automation Drives series. It converts fixed-frequency three-phase mains power into a regulated output that allows plant controllers to adjust induction motor speed and torque in applications such as conveyors, pumps, and mixers. The unit fits directly into standard control panels and exchanges process data with PLCs through its integrated I/O and fieldbus options, providing closed-loop motor control in industrial automation systems.

This model delivers 0.75 kW of continuous power, equivalent to 1.0 HP, and is intended for three-phase power grids. Its adjustable output extends up to 590 Hz, allowing oversynchronous operation for high-speed spindles, while its starting-torque capacity of 160% for 60 seconds supports heavy breakaway loads. The drive maintains voltage-to-frequency symmetry within a 3.0% phase imbalance and limits power-up cycling to two starts per minute to protect its semiconductors. Analog feedback is processed through a 12-bit converter, digital inputs tolerate up to 28 V DC, and digital outputs supply 40 mA for relays or indicators. VVC+ vector control builds rated flux in 10 ms. In sensorless flux mode, torque steps reach their full value in 1 ms, and the frequency can be raised to 300 Hz without encoder feedback.

Energy performance meets the IE2 efficiency class, and full current is maintained at altitudes up to 1000 m and ambient temperatures up to 45 °C without derating. Cable runs of up to 150 m are supported with shielded conductors, while unshielded installations can use twice that length for remote motor placement on large machines. The inverter tolerates 110% overload torque for 0.5 seconds to handle brief transients. It accepts both shielded and unshielded motor leads, allowing EMC filtering to be matched to site requirements.

Analog Output Resolution
12 bit
Efficiency Class
IE2
Flux Torque Rise
1 ms
Horse Power
1.0 HP
Max Altitude No Derating
1000 m
Max Ambient At Full Current
45 °C
Max Digital Input Voltage
28 V DC
Max Digital Output Current
40 mA
Max Flux Mode Freq
300 Hz
Max Input Powerups
2/min
Max Output Frequency
590 Hz
Max Phase Imbalance
3.0%
Max Shielded Cable
150 m
Max Unshielded Cable
300 m
Overload Torque
110% for 0.5 s
Power Phase
Three Phase Power
Power rating
0.75 KW
Product Group
VLT AutomationDrive FC
Series Identifier
302
Starting Torque
160% for 60 s
Vvc+ Torque Rise
10 ms

Frequently Asked Questions about FC-302PK75T:

Q: What is the analog output resolution of the Danfoss FC-302PK75T?

A: The FC-302PK75T features a 12-bit analog output resolution for precise control signals.

Q: What efficiency class does the FC-302PK75T belong to?

A: This drive is classified as IE2 for efficiency, meeting specific performance standards.

Q: What is the maximum output frequency of the FC-302PK75T automation drive?

A: The maximum output frequency supported by this model is 590 Hz.

Q: What is the maximum altitude at which the FC-302PK75T can operate without derating?

A: The FC-302PK75T supports operation at altitudes up to 1000 meters without derating.

Q: What is the starting torque capability of the FC-302PK75T?

A: This drive can deliver a starting torque of 160% for up to 60 seconds.