FC-302PK37T5131G5990H2BGXXXXSXXXXAXBXCXXXXDX

Ask for Availability

Preparing your secure checkout page...

The FC-302PK37T5131G5990H2BGXXXXSXXXXAXBXCXXXXDX drive boasts a power rating of 7.5 kW, dimensions of 594 mm in height, 242 mm in width, and 319 mm in depth, and IP66 protection. Part of the VLT FC 302 Automation Drives series from Danfoss, it features forced air cooling and compatibility with Modbus RTU and BACnet communication protocols.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Danfoss manufactured the FC-302PK37T5131G5990H2BGXXXXSXXXXAXBXCXXXXDX. The power rating is 7.5 kW. For applications that need lots of torque and speed, this means the drive can deliver a lot of power to the connected motor. 7.5 kW is just the rate at which electrical energy is converted into mechanical work. For heavy equipment, pumps and fans to run reliably and robustly in industrial environments, this power is crucial. Physical dimensions are 35kg and 594mm high, 242mm wide, and 319mm deep. The weight and size of the drive determine its build and space requirements. Putting the internal electrical components in a metal enclosure makes it more durable. IP66 is suitable for industrial applications as it means high protection against dust and high-pressure water jets.

For the drive to be reliable and long-lasting in tough conditions, this level of ingress protection is necessary. Its ability to adapt to changing environments is further shown by its operating temperature range of -25C to 50C. The drive runs at 50/60Hz with 3 phase input voltage of 380-480V. These are standard requirements for industrial power systems so, it’s compatible with common power sources. The drive can handle short power spikes with its 150% overload for 60 seconds, which is necessary for applications with varying loads.

To maintain ideal operating temperatures and avoid thermal overload, the forced air cooling system distributes the heat from the electrical components. This cooling is necessary for the drive to be consistent and reliable, especially when carrying heavy loads. An important part of this is communication. BACnet and Modbus RTU protocols support and make integration with industrial automation systems easy. These protocols allow for data sharing, monitoring and control between drives and different automation systems. The drive can also preserve power quality and reduce interference with other electronic devices with its harmonic distortion of less than 35% at full load. It can also run different types of motors, which widens its application in many scenarios.

Communication
Modbus RTU, BACnet
Cooling Method
Forced Air Cooling
Dimensions
Height: 594 mm, Width: 242 mm, Depth: 319 mm
Display
LED display for status and diagnostics
Enclosure Material
Metal
Frequency
50/60 Hz
Harmonic Distortion
<35% at full load
Input Voltage
Three Phase 380-480 V
Ip Class
IP66
Operating Temperature
-25C to 50C
Overload Capacity
150% for 60 seconds
Power Rating
7.5 kW
Weight
35 kg

Frequently Asked Questions about FC-302PK37T5131G5990H2BGXXXXSXXXXAXBXCXXXXDX:

Q: What is the power rating of the Danfoss VLT AutomationDrive FC-302PK37T5131G5990H2BGXXXXSXXXXAXBXCXXXXDX?

A: The drive has a power rating of 7.5 kW, making it suitable for a variety of industrial applications that require precise motor control and energy efficiency.

Q: What are the dimensions and weight of this drive?

A: The drive has a height of 594 mm, a width of 242 mm, and a depth of 319 mm. It weighs approximately 35 kg, ensuring a compact yet sturdy design for industrial environments.

Q: What type of motors can this drive control?

A: The Danfoss VLT FC 302 Automation Drives can control AC induction motors, permanent magnet synchronous motors, AC induction servomotors, and synchronous reluctance motors, offering high flexibility for different industrial needs.

Q: What communication protocols does the drive support?

A: It supports Modbus RTU and BACnet communication protocols, allowing seamless integration into industrial automation systems and enabling efficient data exchange and control.

Q: What cooling method does the drive use?

A: This model features forced air cooling, which ensures effective heat dissipation and maintains optimal performance even in demanding applications.


Internal Product Review

  • ‘‘The VLT FC 302 Automation Drives is a robust and versatile drive designed to meet the demands of a broad spectrum of industrial applications. Its modular design allows for easy customization and adaptability to specific needs. The drive's support for multiple motor types and communication protocols enhances its flexibility, making it a good choice for various system integration requirements. Features like droop for load sharing and integrated brake control contribute to its suitability for complex applications. The inclusion of automatic motor adaptation (AMA) and various commissioning tools streamlines the setup process, saving time and effort.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo