FC-302P7K5T5E20H1XG Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-302P7K5T5E20H1XG is part of the VLT FC 302 Automation Drives series and has a power rating of 7.5 kW or 10 HP. It operates on three phase power with a mains voltage of 380 to 500 VAC, and features an IP20 protection level. This drive comes with a graphical local control panel and is designed for normal cabinet mounting with A, B, and C frames.
Internal Product Review
The FC-302P7K5T5E20H1XG is a Danfoss VLT FC 302 automation drive designed for three-phase power and 380 - 500 VAC mains. The 7.5 kW rating and graphical local control panel support efficient commissioning and dependable process control. IP20/chassis protection and an RFI Class A1/B (C1) filter make the drive especially appealing for clean cabinet integration.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-302P7K5T5E20H1XG is an AC variable frequency drive produced by Danfoss for the VLT FC 302 Automation Drives series. It belongs to the VLT AutomationDrive FC product group and uses the series identifier 302. The unit converts fixed-frequency mains power into a regulated output that lets control systems adjust induction motor speed and torque in conveyors, pumping stations, and process lines where efficient and accurate motor control is required. This control method helps the driven equipment respond smoothly to changing load conditions and process demands during normal operation.
This drive accepts a mains supply of 380–500 VAC, and its terminals are designed for three-phase power, allowing direct connection to common industrial grids. Its continuous output is rated at 7.5 kW, which corresponds to 10 HP at the motor shaft. An IP20 chassis enclosure keeps live parts finger-safe inside a ventilated installation space, so the unit must be mounted in a cabinet when higher ingress protection is needed. The drive includes an internal Safe Stop function, while regenerative energy must be handled externally because there is no integrated brake chopper. Power electronics are cooled by natural convection through the heat sink fins, which supports cabinet layouts that maintain clear airflow around the unit.
Conducted emissions are limited by an RFI Class A1/B (C1) filter, enabling installation on sensitive plant networks without extra suppression modules. Emergency deceleration relies on a no brake chopper configuration, so excess kinetic energy must be absorbed by the motor load or an external resistor. Local parameter access is handled through a graphical local control panel that shows real-time status and simplifies setup. Mechanical integration follows normal cabinet mounting for A, B, and C frames, so fastening points and spacing remain consistent with other FC 302 sizes in the same enclosure layout.