The FC-302P75KT5P55H1BGXXXXSXXXXAXBXCXXXXDX is a three-phase automation drive from Danfoss, part of the VLT FC 302 Automation Drives series. It supports 380 to 500 VAC mains voltage and delivers a power rating of 75 kW or 100 HP. The drive features a graphical local control panel, a brake chopper, and an RFI Class A1/B filter.
Internal Product Review
The FC-302P75KT5P55H1BGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 302 automation drive rated for 75 kW and 100 HP. Three-phase 380 - 500 VAC input gives the drive strong compatibility with standard industrial power systems. The graphical local control panel and brake chopper make the unit a very capable choice for precise setup and controlled stopping.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-302P75KT5P55H1BGXXXXSXXXXAXBXCXXXXDX is a variable-frequency drive built by Danfoss for the VLT FC 302 Automation Drives series. It converts fixed-frequency mains power into a regulated output that allows control systems to adjust induction-motor speed and torque. This capability can improve process control and energy use in automated conveyors, pumps, fans, and other variable-speed machinery. The unit belongs to the VLT AutomationDrive FC product group and carries the internal series identifier 302.
The power section delivers a motor output of 75 kW, which is equivalent to 100 HP. The inverter accepts an incoming supply of 380 – 500 VAC through a three-phase power input. This input range supports direct connection to compatible industrial power systems without requiring voltage conversion. An integrated brake chopper routes regenerated energy to a connected braking resistor whenever commanded deceleration returns more energy than the motor can dissipate. This function helps prevent excessive DC-bus voltage during rapid stops or when controlling loads with high inertia. Because the mains option slot is empty, any line reactors, disconnects, or fuses required by the installation must be mounted separately.
Electromagnetic interference is reduced by the built-in RFI Class A1/B (C1) filter, which can reduce the need for separate suppression components in suitable installations. Operators configure parameters through the Graphical Local Control Panel, where plain-text menus make operating values and drive settings easier to review. The standard language pack supports menu navigation, and settings can be copied between compatible units with the detachable control panel. The drive has uncoated circuit boards, so it should be installed in a clean, dry cabinet that protects its electronics from moisture, conductive dust, and corrosive contaminants. Standard cable entries simplify gland-plate preparation and allow power, motor, and control wiring to be routed through separate openings. The empty option bays provide the standard drive configuration without additional fieldbus, motion-control, or application-specific modules.