FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX is part of the VLT AutomationDrive FC 302 Series and has a maximum temperature of 45°C. With a frequency of 50/60 Hz, it supports a conductor cross-section of 4 mm², assuming IP55 or IP66 enclosure. The drive has an EMC level of Class A with a rated leakage current of 35 mA.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX is an exquisite frequency converter made by Danfoss for variable adjustment of three-phase motors. Released under the VLT Automation product line, this frequency converter is fit for various types of applications and industrial systems. It requires a three-phase voltage supply on its input terminals with a maximum temporary imbalance of 3%. Depending on the applied drive voltage, the current rating of this device will vary. Regardless of the drive voltage, however, the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX maintains a typical shaft output of 1.1 kW or 1.5 horsepower. At this shaft output, the converter has an estimated power loss of 58 to 63 watts, depending on the mains voltage.

With an A2 enclosure, the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX has a protection rating of IP 20. During high-overload operating conditions, the frequency converter achieves a continuous output current of 2.7 to 6.6 A. For lower excitation voltages, the converter delivers higher output current. Conversely, for higher supply voltages, the output current decreases. The FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX has a nominal or rated efficiency of 96% and requires a set of 4 sq. mm or 12 AWG cables for the mains, brake, and motor. At rated conditions, the converter achieves a minimum true power factor of 90%.

Like all other frequency converters manufactured by Danfoss with a 302 drive, the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX supports different control principles such as the U/f, VVC, and flux mode. At standard operating conditions, the variable drive has an output frequency of 0 to 590 hertz. When operated in flux mode, however, the converter has a motor output frequency of 0 to 300 hertz. The FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX has an energy efficiency class of IE2 and a maximum true harmonic distortion (THD) of 10%.

Ambient temp range
0 to 45 C
Cable cross-section for mains, motor, brake
12, 12, 12 AWG
Continuous output current
2.7 to 6.6 A
Dimensions
268 x 90 x 205 mm
Efficiency
96 percent
Emc Level
Class A
Energy efficiency
IE2
max THD
0.1
Maximum Temperature
50°C
Motor output frequency range
0 to 590 hz
Motor output frequency range (flux mode)
0 to 300 hz
Power Loss
58 to 63 watts
Rated Leakage Current
3.5 mA
Supported supply frequency
50/60 Hz
Weight
4.9 kg

Frequently Asked Questions about FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX:

Q: What is the recommended fuse size for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX?

A: With a mains voltage of 200-240 V, the recommended fuse size for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX is gG-10.

Q: What is the recommended circuit breaker for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX?

A: With standard mains voltage, the recommended circuit breaker size for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX is PKZM0-25.

Q: What is the maximum trip level for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX?

A: The maximum trip level for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX with an A2 enclosure and supply voltage of 200-240 V is 25 A.

Q: How many programmable relay outputs can the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX support?

A: The FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX can support up to two programmable relay outputs during operation.

Q: What terminals are dedicated for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX’s RS485 control card?

A: The RS485 control card for the FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX can be connected to terminals 68 and 69, with the common terminal being terminal 61.


Internal Product Review

  • ‘‘The FC-302P1K1A2131B0407H2XGXXXXSXXXXAXBXCXXXXDX is an original creation of Danfoss, boasting a powerful 302 drive. With robust support for various control modes, this frequency converter is suitable for a wide range of situations and applications. It facilitates dynamic motor control while maintaining safe operating conditions.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo