The Danfoss FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX frequency converter delivers precise motor control with an output frequency resolution of 0 to 590 Hz and a system response time of ≤ 2 ms. It supports a closed-loop speed control range of 1:1000. The model also features advanced torque regulation.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Danfoss is a global manufacturer specializing in energy efficient solutions for industrial automation and power electronics. The FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX Frequency Converter is designed for high performance motor control applications. It provides precise speed and torque regulation for various industrial automation and HVAC systems.
This <
This FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX frequency converter is equipped with a torque limit feature designed to protect the motor from overload regardless of its operating speed. The torque limit function operates in two modes: Torque Limit Motor Mode which regulates and limits torque when the motor is actively driving a load and Torque Limit Generator Mode which controls torque when the motor acts as a generator. The Trip Delay at Torque Limit parameter determines how long the system allows torque to exceed the set limit before triggering a warning.
Frequently Asked Questions about FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX:
Q: How does the Danfoss FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX ensure precise speed control?
A: This model features an output frequency resolution of 0 to 590 Hz. It maintains an open-loop speed accuracy of 30 - 4000 rpm with an error margin of ± 8 rpm.
Q: What is the system response time of the Danfoss FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX?
A: The system response time is ≤ 2 ms. This ensures rapid motor adjustments and seamless performance in demanding industrial applications.
Q: How does the torque limit function of the Danfoss FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX protect the motor?
A: It regulates torque in two modes: Torque Limit Motor Mode and Torque Limit Generator Mode. These functions prevent overload and maintain stability at any operational speed.
Q: What is the accuracy of the closed-loop speed control in the Danfoss FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX?
A: The closed-loop control range extends to 1:1000. It maintains an accuracy of 0 - 6000 rpm with an error margin of ± 0.15 rpm.
Q: How does the Danfoss FC-302N90KT5134F0298H2XGXXXXSXXXXAXBXCXXXXDX maintain precise torque control?
A: It uses speed feedback to regulate torque with a maximum error of ± 5% of the rated torque. This ensures consistent motor performance under varying load conditions.