4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX Danfoss

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 302 automation drive designed for stable three-phase motor control on 380–500 VAC mains. Output capability to 590 Hz and starting torque of 160% for 60 s support demanding acceleration and precise speed regulation. An included brake chopper and Category 3 EMC performance make the unit a strong choice for industrial drive applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX is a Danfoss AC variable frequency drive in the VLT FC 302 Automation Drives series. Within an automation cell, it converts fixed-frequency three-phase mains power into a regulated output that allows controllers to match motor speed and torque to real-time load demands. The integrated brake chopper manages regenerative energy during deceleration, while the Category 3 EMC design limits conducted and radiated interference. The LCP 102 local control panel provides direct access to operating data and adjustable parameters. These features support conveyors, pumps, and general material-handling systems that require fast torque response and accessible local controls.

This drive accepts a three-phase input of 380–500 VAC at 50 or 60 Hz, with a frequency tolerance of ±5%. It provides an output frequency range of 0–590 Hz, allowing the inverter to support constant-torque applications and high-speed vector operation. In flux mode, torque builds in 1 ms, while the VVC+ algorithm reaches rated torque in 10 ms for predictable acceleration control. A starting capability of 160% for 60 seconds supports demanding loads such as positive-displacement pumps. The output voltage has a range of 0–100% of the supply voltage, allowing the drive to regulate motor voltage across its operating range. Flux-optimized regulation remains available down to 0 Hz for controlled operation at standstill and low speed. A standard language pack supports local menu access, and I/O shield monitoring helps maintain signal integrity in electrically noisy installations.

Continuous full-load operation is permitted at ambient temperatures up to 45 °C. The thermal algorithm maintains the drive’s rating at installation altitudes below 1000 m. Short overload events are supported at 110% for up to 0.5 seconds, providing additional capacity during brief load changes. The drive accepts shielded motor cables up to 150 m long, while unshielded motor cables may be as long as 300 m. These cable allowances accommodate installations in which the drive and motor are separated by long machine routes. The integrated EMC filter meets Category 3 emission requirements, so the drive does not include the separate C1 filter option.

Brake Chopper
Included
C1 Option
No C1 Option
Emc Category
Category 3
Flux Mode Frequency
0–300 Hz
Language Pack
Standard
Local Control Panel
LCP 102
Mains Voltage
380 - 500 VAC
Max Altitude No Derating
1000 m
Max Ambient At Full Current
45 °C
Output Frequency
0–590 Hz
Output Voltage
0–100% of supply voltage
Overload Torque
110% up to 0.5 s
Power Phase
Three Phase Power
Product Group
VLT AutomationDrive FC
Series Identifier
302
Shielded Motor Cable
150 m
Starting Torque
160% for 60 s
Supply Frequency
50/60 Hz ±5%
Torque Rise Time Flux
1 ms
Torque Rise Time Vvc+
10 ms
Unshielded Motor Cable
300 m

Frequently Asked Questions about FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX:

Q: Does the FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX drive have a brake chopper included?

A: The FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX drive includes a brake chopper as a standard feature.

Q: What is the mains voltage range supported by the FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX automation drive?

A: This drive can be operated on mains voltages from 380 to 500 VAC.

Q: What output frequency range is available on the FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX drive?

A: The output frequency of this drive can be set from 0 to 590 Hz, allowing for fine motor speed control.

Q: What starting torque capability does the FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX provide?

A: A starting torque of 160% for up to 60 seconds is supported by this drive.

Q: How long can the shielded motor cable be when using the FC-302N200T5134H3688H2BGXXXXSXXXXAXBXCXXXXDX drive?

A: This drive permits shielded motor cable lengths up to 150 meters.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo