The FC-302N132T7134G0911H2XGCXXXSXXXXAXBXCXXXXDX is an automation drive from Danfoss, part of the VLT FC 302 Automation Drives series. It supports three phase power and operates at a mains voltage range of 525 to 690 VAC. The drive includes a standard language pack and belongs to the VLT AutomationDrive FC product group.
Internal Product Review
The FC-302N132T7134G0911H2XGCXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 302 automation drive built for three-phase power at 525 - 690 VAC. Standard language pack and no adaptation simplify setup, making the drive a dependable choice for high-voltage automation applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-302N132T7134G0911H2XGCXXXSXXXXAXBXCXXXXDX is an AC variable-frequency drive produced by Danfoss for the VLT FC 302 Automation Drives series. Acting as a plant-level inverter, it converts fixed mains power into a modulated output that allows controllers to regulate induction-motor speed and torque. This electronic control reduces the need for mechanical throttling and can improve energy efficiency in conveyors, pumps, and material-handling equipment. Within an automation cell, the drive interfaces directly with PLC logic to apply programmed acceleration ramps, overload thresholds, and protective monitoring during continuous operation.
The input stage accepts 525–690 VAC, allowing direct connection to compatible high-voltage networks without external transformers. The inverter uses three-phase power, drawing balanced input current and delivering a symmetrical output to standard IEC motors. The drive has no adaptation module in slot B, leaving that option position unoccupied for applications that may require a compatible module later. Built-in protective functions monitor operating conditions that could damage the drive or connected motor. An undervoltage trip responds when the supply falls below the permitted level, while motor phase-loss detection identifies an interruption in the output connection.
The drive has no integrated C1 filter, so an external C1 filter must be installed when that level of electromagnetic compatibility is required. This external filtering may be necessary when the drive operates near sensitive instrumentation or in locations with stricter limits on conducted emissions. The operator interface uses the Standard language pack, providing the default set of languages for menu navigation and parameter entry. Additional supported languages can be loaded through compatible memory cards when multilingual operation is needed. The numeric identifier 302 links the control hardware to related drive configurations within the same automation-drive platform.