136Z4872 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: FC-302P45KT5E20H2XNCDXXSXXXXAQBUCXXXXDX
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
49 Seconds
The Danfoss 136Z4872 is part of the VLT FC 302 Automation Drives series and is rated for 60 horsepower with a power rating of 45 kW. It operates on three phase power at 380 to 500 VAC and features a Modbus TCP MCA 122 A option along with a MCB-103 resolver B option. This drive is cabinet mounted with IP20 chassis protection, has a coated PCB, and includes a numerical local control panel.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 136Z4872 is a variable frequency drive manufactured by Danfoss for the VLT FC 302 Automation Drives series. Within industrial automation systems, this unit modulates the speed and torque of induction or permanent-magnet motors so production lines, pumps, and material-handling equipment can match real-time process demands. It rectifies the incoming AC supply and inverts it into a controlled output frequency, allowing the connected motor to respond accurately to programmable control commands as process conditions change during operation. This operating method helps match motor output to varying load demands instead of forcing the motor to run at a constant fixed speed.
Continuous output is rated at 45 kW, which corresponds to 60 HP. The drive accepts 380–500 VAC mains and uses three-phase power, enabling balanced current draw across industrial feeders and supporting stable operation with common industrial supply systems. Its housing has an IP20 chassis design, so it is intended for protected cabinet installation rather than open mounting. Normal cabinet mounting for A, B, and C frames and standard cable entries simplify panel layout, while the included language pack supports routine setup and operation.
The A-slot carries a Modbus TCP MCA 122 card for Ethernet-based control and diagnostics, while the B-slot hosts an MCB-103 resolver board for legacy feedback integration. Because no brake chopper is installed, dynamic stopping must rely on external hardware, and the adaptation field is set to no adaptation. The C, C0, C1, and D slots are empty. An on-drive Numerical Local Control Panel provides direct parameter entry when network access is unavailable. Conducted emissions are reduced by the integrated RFI Filter, and a coated PCB helps resist moisture and airborne contaminants during extended cabinet service.
Frequently Asked Questions about 136Z4872:
Q: What is the horsepower rating of the Danfoss 136Z4872 VLT FC 302 drive?
A: The 136Z4872 drive is rated for 60 HP, suitable for high-power industrial applications.
Q: What mains voltage range does the 136Z4872 drive support?
A: This model is compatible with 380 to 500 VAC mains voltage input.
Q: Which connectivity option is included in the 136Z4872 drive?
A: The 136Z4872 includes a Modbus TCP MCA 122 as its A Option, enabling Modbus TCP connectivity.
Q: What protection rating does the Danfoss 136Z4872 VLT FC 302 drive offer?
A: The 136Z4872 provides an IP20/chassis protection level for safe cabinet installation.
Q: What type of local control panel comes with the 136Z4872 VLT FC 302 drive?
A: This drive features a numerical Local Control Panel (LCP) for input and monitoring.