135U1345 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: FC-302P4K0T5E20H2BGXXXXSXXXXALBUCXXXXDX
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
48 Seconds
The Danfoss 135U1345 is part of the VLT FC 302 Automation Drives series and delivers 5 HP and 4.0 kW of power. It features a PROFINET MCA 120 option, an MCB-103 Resolver, and supports three-phase power at 380 to 500 VAC. The drive comes with an IP20 chassis protection level, RFI filter, and a graphical local control panel, measuring 268 mm in height, 220 mm deep, and 90 mm wide.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The Danfoss 135U1345 is a variable-frequency drive in the VLT FC 302 Automation Drives series. It converts fixed-frequency three-phase mains into a controllable waveform so that induction or permanent-magnet motors can start, stop, and change speed under PLC command. By varying output frequency and voltage, it lets the connected motor follow process demand while reducing abrupt mechanical stress during speed changes. In production lines, conveyors, or pumping skids, the unit links process logic to motor torque while its brake chopper absorbs regenerated energy during fast stops.
The inverter supplies up to 4.0 kW of continuous power, equal to 5.0 HP, making it suitable for mid-range mechanical loads. It accepts an input range of 380 – 500 VAC on three-phase power, so it can be wired directly to standard plant busbars used in industrial facilities. The IP20 / Chassis enclosure requires installation inside a control cabinet rather than open exposure on the machine. Harmonic noise is reduced by the integrated RFI filter, and the safe-stop circuit works with the brake chopper during controlled deceleration. The drive weighs 4.36 kg, which supports flexible panel placement without adding much load to the enclosure backplate. Parameter access is handled through the graphical local control panel, which gives local visibility for operating values and settings.
The housing has a width of 90 mm, a height of 268 mm, and a depth of 220 mm, which matches the A2 frame and helps preserve airflow in compact enclosures. Network integration is available through the PROFINET MCA 120 option card, and an MCB-103 resolver board can be added when feedback control is required. Standard cable entries simplify gland installation and help keep wiring paths organized inside the cabinet. The PCB is not coated, so the drive is best suited for clean, dry environments where dust and moisture are controlled. Heat sinks remain aligned with vertical airflow in the normal cabinet orientation, which supports stable cooling during operation.
Frequently Asked Questions about 135U1345:
Q: What communication interface is integrated as the A Option on the Danfoss 135U1345?
A: The 135U1345 features a PROFINET MCA 120 communication module as the A Option.
Q: What type of power phase does the Danfoss 135U1345 use?
A: This drive supports three phase power input for operation.
Q: What are the power rating and horsepower for the 135U1345 VLT FC 302 drive?
A: The drive has a power rating of 4.0 kW and a horsepower of 5.0 HP.
Q: Does the Danfoss 135U1345 feature a brake chopper for safe stop?
A: The 135U1345 includes a brake chopper for safe stop functionality.
Q: What mounting style and protection level does the Danfoss 135U1345 have?
A: It is rated for cabinet mounting on A, B, and C Frames and has an IP20 / chassis protection level.