131B0476
Wake Industrial LLC is not an authorized distributor of this product.
MPN: FC-302P5K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The 131B0476 automation drive delivers a power rating of 30 kW (40 hp) at 380-500 V with a starting torque of 160% for 60 seconds. Manufactured by Danfoss as part of the VLT FC 302 Automation Drives, it operates at a mains supply frequency of 50/60 Hz ±15% and features a protection class of IP21/Type 1, IP55/Type 12, or IP66/Type 4X.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 131B0476 is a VLT FC-302 drive from Danfoss with the product code FC-302P5K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0 that is designed for industrial motor control systems. It offers a nominal output power of 5.5 kW that is equivalent to 7.5 HP and it operates on three-phase mains voltage source from 380 VAC to 500 VAC.
The 131B0476 drive possess an enclosure type of IP20 chassis that is classified as E20 and its compact design provides a height of 268 mm, its width is 130 mm and the depth is 205 mm. While with alternate mounting the width increases to 190 mm and the depth to 220 mm. It includes an RFI filter in compliance with class A1/B for conducted emissions and a brake chopper is provided as well for safe motor stop. This drive uses a graphical local control panel for easy operation and its PCB is uncoated, which is classified as 3C2 standard. It features continuous output current of 13 A at 380 – 440 V and 11 A at 441 – 500 V, while its intermittent output current for 60 seconds reaches 20.8 A at 380 – 440 V and at higher mains voltage the intermittent current is 17.6 A. The 131B0476 drive’s rated apparent power is 9.01 kVA and its power failure ride-through capacity is measured as 187 W.
The 131B0476 drive supports induction motors, permanent magnet motors and synchronous reluctance motors. Its ramp time settings range from 0.01 to 3600 seconds and it includes safe torque off functionality in accordance with IEC 61800-5-2. The unit’s fieldbus communication includes PROFIBUS DP MCA 101 and a backup option is provided with the MCB-107 24 V DC supply. Its output frequency range is 0 - 590 Hz and in flux mode it is specified as 300 Hz.
Frequently Asked Questions about 131B0476:
Q: What is the benefit of the RFI filter?
A: The RFI filter suppresses electromagnetic interference, improving compliance with conducted emissions standards. It ensures minimal disturbance to nearby sensitive equipment and longer system reliability.
Q: What is the role of Safe Torque Off in the product code FC-302P5K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0?
A: Its safe torque off (STO) prevents torque generation by cutting motor power safely without removing supply voltage. It enhances safety compliance and allows easy integration into safety circuits.
Q: What is the significance of flux mode up to 300 Hz in this model?
A: The flux mode maintains motor flux stability when output frequency exceeds normal operating range. This prevents magnetic saturation and preserves torque and motor lifespan.
Q: What is the advantage of the 0.01-3600 seconds ramp time in this drive?
A: Its very short ramp times like 0.01 s allow rapid response to control commands, reducing operation delays. Very long ramps up to 3600 s enable smooth, gradual starts for heavy loads and minimal mechanical stress.
Q: what way does the graphical local control panel improve usability?
A: The panel provides intuitive navigation of settings and real-time feedback, streamlining commissioning and diagnostics. Operators can adjust parameters directly onsite without needing specialized tools.