131B0452 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: FC-302P1K1T5E20H1XGXXXXSXXXXA0BXCXXXXDX
The Danfoss 131B0452 is part of the VLT FC 302 Automation Drives series and operates at 380 to 500 VAC with three phase power. This drive has a power rating of 1.1 kW or 1.5 HP and features a graphical local control panel. It has standard cable entries, includes an RFI filter Class A1/B (C1), and is protected to IP20 with normal cabinet mount configuration.
Internal Product Review
The 131B0452 is a Danfoss VLT FC 302 automation drive well suited for three-phase 380 to 500 VAC installations. PROFIBUS DP V1 communication and a graphical local control panel support efficient commissioning and dependable network integration. IP20/chassis protection makes the 1.1 kW unit a strong choice for controlled cabinet applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 131B0452 is an AC variable-frequency drive produced by Danfoss for the VLT FC 302 Automation Drives series. In automated plants, it modulates the output frequency supplied to an induction motor so users can adjust speed, torque, and energy use without mechanical throttling. The drive installs in standard control enclosures and is intended for cabinet-mounted applications where space, wiring access, and protection from surrounding conditions are managed inside the panel.
The unit delivers a continuous mechanical output of 1.1 kW, equivalent to 1.5 HP, allowing it to run small pumps, fans, or conveyors under normal industrial duty cycles. Its input section accepts mains power from 380 to 500 VAC through a three-phase power supply, so it can be wired directly to common 50 or 60 Hz plant feeders without an external transformer. For enclosure integration, the chassis has an IP20 protection rating; live parts are protected against accidental finger contact, while heat can dissipate through filtered cabinet airflow without sealed cooling passages. The mechanical format is compatible with standard A, B, and C frame positions, so the heat sink can align with the available busbar and duct clearances inside the enclosure.
An internal line filter meets RFI Class A1/B (C1) requirements to limit conducted emissions that could affect sensitive instrumentation. Network integration is handled by the A-slot option card, which is a PROFIBUS DP V1 MCA 101 module that supports cyclic control words and status feedback between the drive and a PLC. Local interaction is provided through a detachable graphical local control panel, allowing access to parameters and real-time operating data without opening the cabinet door. Adaptation B uses the no-adaptation setting, leaving the field parameters available for application-specific configuration. Cable terminations pass through the standard gland plate, and the uncoated printed circuit boards are intended for clean, dry electrical rooms where conformal coating is unnecessary.