4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

131B0152 Danfoss

Available, Ships in 1-2 weeks
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 131B0152 is a Danfoss VLT FC 302 automation drive rated at 7.5 kW for 380-500 VAC systems. Operation is efficient and well suited for panel installations, with 0.97 efficiency and an IP20 enclosure. The graphical LCP adds practical commissioning value, making this unit a strong choice for consistent drive control.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131B0152 is an AC variable frequency drive produced by Danfoss as part of the VLT FC 302 Automation Drives series. This converter regulates the speed of three-phase induction motors by converting fixed-frequency mains power into a pulse-width-modulated output. It is used with pumps, fans, and conveyor sections where accurate speed control and reduced energy consumption are required. The compact housing mounts inside a cabinet and provides full parameter access through a detachable keypad.

It accepts a three-phase supply between 380–500 VAC and delivers a continuous motor output of 7.5 kW within this range. The continuous motor current is 14.5 A, while the converter’s apparent input demand reaches 11.6 kVA at 460 V. Its operating efficiency is 0.97, reducing wasted energy and easing panel cooling requirements. The housing has an IP20 protection rating, so the unit must be installed in a clean, ventilated enclosure. The A3 frame size conserves cabinet space, while the conformally coated printed circuit board provides resistance to moisture. A graphical local control panel serves as the local control interface and provides access to operating parameters. The drive does not include a brake chopper, making it suitable for applications that do not require regenerative braking.

During acceleration or brief overloads, the drive can supply 23.2 A to the motor, providing a margin for typical startup peaks. Internal dissipation rises under these conditions, but the estimated heat loss is limited to 255 W, which can be used to determine enclosure ventilation needs. Compliance with EN 55011 Class A2 supports electromagnetic compatibility in industrial installations. Upstream protection is straightforward because the maximum mains current is 13 A and the recommended line fuse is a 32 A gG fuse. Interference-suppression components are included on the coated circuit board to reduce conducted electrical noise. The three-phase rectifier operates without derating across the 441–500 V range associated with the intermittent current rating.

Brake Chopper
None
Continuous Apparent Power
11.6 kVA (460 V)
Continuous Output Current
14.5 A (441-500 V)
Efficiency
0.97
Emc Class
EN 55011 Class A2
Enclosure Rating
IP20
Estimated Power Loss
255 W
Frame Size
A3
Input Phases
3
Input Voltage
380-500 VAC
Intermittent Output Current
23.2 A (441-500 V)
Local Control Panel
Graphical LCP
Max Input Current
13 A (441-500 V)
Max Pre-fuse
32 A
Pcb Coating
Coated PCB
Power Rating
7.5 kW

Frequently Asked Questions about 131B0152:

Q: Does the Danfoss 131B0152 drive come with a brake chopper?

A: The 131B0152 model does not include a brake chopper feature.

Q: What is the continuous output current range for the 131B0152?

A: This drive supports a continuous output current of 14.5 A when supplied with 441-500 V.

Q: What type of input power does the 131B0152 require?

A: The Danfoss 131B0152 is rated for operation on a 380-500 VAC three-phase input.

Q: What is the enclosure rating of the 131B0152 drive?

A: The enclosure carries an IP20 rating, providing basic protection against solid objects but no protection against liquids.

Q: What is the maximum pre-fuse size for the 131B0152 drive?

A: The maximum pre-fuse recommended for this model is 32 A.