4.94 based on 222 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

FC-202PK75T2131G9670 Danfoss

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC-202PK75T2131G9670 is a Danfoss VLT FC 202 AQUA drive rated at 0.75 kW for three-phase power applications. Efficient 0.95 performance and a 50 °C ambient temperature capability make this drive a strong fit for demanding process control. Flexible installation support stands out with motor cable allowances up to 150 m shielded and 300 m unshielded.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202PK75T2131G9670 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. Designed as a pump-oriented controller, the unit converts three-phase mains power into a regulated output that responds to changing flow demands in water and wastewater systems. The drive adjusts motor speed to maintain the pressure or flow required by the process rather than relying on throttling valves. This method can reduce unnecessary energy consumption in filtration systems, irrigation equipment, pumping stations, and municipal supply networks. Its control functions also allow connected pumps to accelerate and decelerate smoothly as demand changes, reducing abrupt mechanical stress on the motor and piping.

The drive accepts a three-phase supply within the 200–240 VAC range and draws an input current of 4.1 A at full load. Its inverter supplies a maximum motor current of 4.6 A to support controlled pump operation. The motor output is rated at 0.75 kW, which corresponds to a mechanical shaft capability of 1.0 HP. This output level allows the device to start and regulate small centrifugal pumps without requiring an unnecessarily large drive. The apparent power demand is 1.66 kVA, which assists with the selection of compatible upstream electrical equipment. A 10 A pre-fuse is recommended to interrupt fault current and protect the incoming power circuit.

At ambient temperatures up to 50 °C, the inverter maintains an operating efficiency of 0.95. Its energy-performance class is IE2, and normal operation produces approximately 54 W of heat that cabinet ventilation must remove. Shielded motor cables can extend to 150 m, allowing the drive to be installed at a distance from pumps in remote equipment rooms. Unshielded motor cable runs may reach 300 m when the installation does not require the additional electromagnetic protection provided by shielding. The controller delivers its rated output without current derating at elevations up to 1,000 m. With linear current reduction applied at higher elevations, the unit can continue operating at locations up to 3,000 m above sea level.

Altitude Derated
3000 m
Altitude No Derate
1000 m
Ambient Temp
50 °C
Apparent Power
1.66 kVA
Efficiency
0.95
Efficiency Class
IE2
Est Power Loss
54 W
Horse Power
1.0 HP
Input Current
4.1 A
Mains Voltage
200 - 240 VAC
Max Pre-fuse
10 A
Motor Cable Shielded
150 m
Motor Cable Unshielded
300 m
Output Current
4.6 A
Power Phase
Three Phase Power
Power Rating
0.75 KW
Product Group
VLT AQUA Drive
Series Identifier
202

Frequently Asked Questions about FC-202PK75T2131G9670:

Q: What is the maximum output current provided by the Danfoss FC-202PK75T2131G9670 drive?

A: The FC-202PK75T2131G9670 drive is rated for a maximum output current of 4.6 A.

Q: What mains voltage range does the FC-202PK75T2131G9670 VLT AQUA Drive support?

A: This drive supports mains voltages ranging from 200 to 240 VAC, making it suitable for common industrial power supplies.

Q: What is the power rating and horsepower of the FC-202PK75T2131G9670?

A: The power rating for this model is 0.75 kW, delivering up to 1.0 horsepower.

Q: What is the maximum shielded motor cable length for the FC-202PK75T2131G9670?

A: With a shielded motor cable, the maximum permissible length is 150 meters.

Q: What is the maximum ambient temperature in which the FC-202PK75T2131G9670 can operate?

A: This model operates efficiently up to an ambient temperature of 50 °C.