FC-202PK55T4131Z2469 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202PK55T4131Z2469 is a VLT FC 202 AQUA Drive with a power rating of 0.55 kW and operates on three phase power at 380 to 480 VAC. It delivers up to 0.75 HP and supports digital input voltages of 0 to 24 V DC with a resistance of 4 kΩ. This model can be used with shielded motor cables up to 150 meters and unshielded cables up to 300 meters.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202PK55T4131Z2469 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. As part of the VLT AQUA Drive product group, it modulates motor frequency to control flow and pressure in water-handling systems used throughout industrial automation. By converting three-phase mains power into regulated output power, the unit supplies speed-dependent torque to centrifugal pumps and aeration blowers. Variable-speed operation can reduce energy consumption and limit mechanical stress on valves, piping, and connected pump components.
The inverter accepts 380–480 VAC through its power terminals and operates with three-phase power, matching standard industrial feeders. Its power section can deliver 0.55 kW (0.75 HP), allowing it to operate compact pump systems without unnecessary oversizing. Upstream circuit protection is provided by a 10 A pre-fuse. Control connectivity includes six digital inputs rated for 0–24 V DC with 4 kΩ resistance, which limits current draw from connected PLC cards. Two digital outputs are available, and each can source up to 40 mA for pilot lights or interlock relays. These input and output channels support the exchange of operating status, start and stop commands, and speed references with supervisory controllers.
The unit remains fully rated from 0 °C through 50 °C and maintains its rated current at elevations up to 1000 m without derating. For feedback functions such as flow metering, its transistor pulse output switches at frequencies up to 32 kHz. Field wiring uses cage-clamp terminals that accept conductors with cross-sectional areas up to 6 mm², while motor conductors are limited to 4 mm². Motor cable runs can reach 150 m when shielded or 300 m when unshielded. These cable allowances support installations in which the drive is mounted at a distance from pumps, blowers, or other water-handling equipment. Appropriate routing and shielding help reduce electrical interference between motor wiring and low-voltage control circuits.