The Danfoss FC-202PK37T4134L2392 is a drive from the VLT FC 202 AQUA Drives series with a power rating of 0.37 kW and an efficiency of 0.93. It operates with a mains voltage of 380 to 480 VAC and delivers a continuous output current of 1.3 A at 380-440 V and 1.2 A at 441-480 V. The drive supports a maximum ambient temperature of 50 °C and allows for shielded motor cables up to 150 meters in length.
Internal Product Review
The FC-202PK37T4134L2392 is a Danfoss VLT FC 202 AQUA drive with a 0.37 kW rating and three-phase 380 to 480 VAC input. Efficiency of 0.93 and digital output capability up to 32 kHz support smooth motor control and economical operation. The drive stands out as a refined low-power solution for demanding AQUA applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202PK37T4134L2392 is a variable frequency drive produced by Danfoss within the VLT FC 202 AQUA Drives series. Designed for pump and blower duties in water-handling systems, the unit adjusts induction motor speed to match flow demand while protecting the mechanical load from operating conditions that could cause damage. By converting three-phase mains power into a modulated output waveform, it supports energy-efficient process control in municipal water systems and industrial automation applications.
The drive accepts three-phase power from 380 to 480 VAC and delivers a continuous output of 0.37 kW, which corresponds to 0.50 HP for small centrifugal pumps. At 400 V, the inverter provides 0.9 kVA of apparent power, and its output current remains 1.3 A on 380–440 V lines or 1.2 A when the supply reaches 480 V. Short-term overload operation raises the output to 2.0 A and 1.8 A, respectively, allowing the motor to accelerate without requiring drive derating. An analog reference can feed a load of 500 Ω, while the transistorized digital output can switch process alarms at frequencies up to 32 kHz. The overall conversion efficiency is 0.93, so most input energy reaches the motor instead of being dissipated as heat. The front end draws a maximum of 1.2 A from the mains, which is appropriate for the drive’s power class and connected motor load.
The inverter operates in ambient air at temperatures up to 50 °C without an output reduction. Panel ventilation must remove internal power losses of 35 W to maintain acceptable operating temperatures. Motor leads may extend to 150 m when shielded or 300 m when unshielded, providing flexibility when pumps are installed far from the control panel. A 10 A prefuse provides line protection for this current range. The three-phase input topology prevents neutral loading when the drive is connected to a balanced electrical supply.