The Danfoss FC-202PK37T2136H9356 belongs to the VLT FC 202 AQUA Drives series and is rated for three phase power with a mains voltage of 200 to 240 VAC. This drive has a power rating of 0.37 kW, delivers 0.50 horsepower, and operates with a continuous output current of 2.4 A. It features an efficiency of 0.94, supports a maximum ambient temperature of 50 °C, and can be installed at altitudes up to 1000 meters without derating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202PK37T2136H9356 is an adjustable-frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. It is intended to regulate centrifugal pumps and blowers, providing automated process control in municipal or industrial water systems. By converting fixed-frequency mains power into a variable-frequency output, the unit allows a PLC to maintain pressure or level setpoints while minimizing energy use and mechanical stress. Dedicated AQUA firmware supports functions such as sleep modes and dry-run detection, making the drive a central component in modern fluid-handling skids.
Rated output power is 0.37 kW, which equates to 0.50 HP, so the drive is suitable for fractional-horsepower motors common in small booster stations. The power section is supplied with 200 to 240 VAC using three-phase power, drawing a continuous input of 2.2 A and delivering 2.4 A to the motor terminals. At 208 V, the apparent input power is 0.86 kVA, providing a simple sizing reference for upstream transformers. Electrical conversion efficiency reaches 0.94, meaning most of the supplied energy is transferred to the motor with only modest thermal loss. Upstream protection is provided by a 10 A prefuse. Motor leads up to 150 m when shielded or 300 m when unshielded can be connected through terminals that accept 4 mm² conductors, while the disconnect side can accommodate 6 mm² conductors.
Internal heat dissipation is specified at 29 W, so enclosure ventilation can be planned without auxiliary cooling. Operation is permitted at altitudes up to 1000 m without derating. Ambient temperatures can range from -10 °C at reduced load or 0 °C at full load up to 50 °C before output-current reduction becomes necessary. The drive remains functional above that temperature but must be derated according to the applicable thermal guidelines. The stated conductor sizes and accepted motor lead lengths simplify cable management while providing predictable voltage drop and electromagnetic compatibility performance.