FC-202P7K5T4131F1080 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P7K5T4131F1080 is part of the VLT FC 202 AQUA Drives series and has a power rating of 7.5 kW with support for three phase power and mains voltages from 380 to 480 VAC. It provides an output of 10 horsepower and features a maximum output frequency of 590 Hz. The drive delivers continuous output and input currents of 14.5 A and 13.0 A respectively at 441-480 V, and it achieves an efficiency of 0.97.
Internal Product Review
The FC-202P7K5T4131F1080 is a Danfoss VLT FC 202 AQUA drive rated for 7.5 kW and 10 HP. Operation on 380 - 480 VAC with three-phase power makes the drive easy to apply in demanding pumping and process installations. A 0.97 efficiency rating and 590 Hz maximum output frequency make this unit a very capable choice for high-performance variable speed control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P7K5T4131F1080 is an AC variable-frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It converts a 380–480 VAC three-phase supply into a regulated output for controlling centrifugal pump speed and torque. This control supports precise water flow, level, and pressure regulation in treatment plants and irrigation systems.
With a 460 V mains supply, the inverter provides a continuous apparent power of 11.6 kVA, indicating the maximum volt-ampere load that it can support without derating. Continuous input current is limited to 13.0 A, while the motor terminals can continuously deliver up to 14.5 A. An efficiency of 0.97 means that approximately 3% of the input energy becomes heat. The resulting estimated power loss is 225 W, which should be considered when arranging cabinet ventilation. With a mechanical output of 10 HP and an electrical power rating of 7.5 kW, the unit is suitable for medium-duty pump applications in Overvoltage Category III installations. It accepts a maximum phase imbalance of 3.0%, helping maintain balanced loading on supply transformers during normal operation.
The drive can operate at ambient temperatures up to 50 °C, provided that cooling airflow remains unobstructed. For high-speed dosing or aeration tasks, the control stage can produce carrier frequencies up to 590 Hz, providing a wide motor speed range. Start-stop operation is limited to two power-ups per minute to reduce stress on the capacitors. Input circuit protection must use a pre-fuse rated no higher than 30 A. During a fault, the output structure can withstand a prospective short-circuit current of 100,000 A rms, allowing coordination with upstream circuit breakers on industrial feeders. Proper protective-device selection helps isolate excessive current before it damages connected wiring or equipment.