4.94 based on 222 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

FC-202P75KT6134F4379 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-202P75KT6134F4379 is a drive from the VLT FC 202 AQUA Drives series designed for three-phase power systems. It delivers a normal overload output of 75 kW with a continuous current of 100 A and achieves an efficiency of 0.98. The drive supports a maximum ambient temperature of 50°C and allows for a shielded motor cable length up to 150 meters.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202P75KT6134F4379 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It belongs to the VLT AQUA Drive product group, and the internal 202 series identifier places it in the line of controllers optimized for water and wastewater pumps. By converting fixed-frequency mains power into a regulated output, the unit allows centrifugal pump speed to be adjusted directly from the drive. This control method helps maintain the required flow and pressure without additional throttling hardware, which can reduce unnecessary mechanical restriction in the pumping system.

This controller is designed for three-phase power networks and reaches a full-load efficiency of 0.98, limiting estimated heat loss to 1500 W. Under high-overload duty, the inverter can continuously supply 83 A, matching a shaft power of 55 kW. Normal-duty operation raises the continuous current to 100 A for 75 kW applications. The corresponding line current is 75 A at 575 V in high-overload mode and 91 A during normal-duty operation. Upstream protection may use a 225 A prefuse, while shielded motor cables can extend up to 150 m without exceeding the drive output limits. The drive tolerates a maximum ambient temperature of 50 °C, so additional cabinet airflow or output derating is required only when the surrounding temperature exceeds this limit.

Short-term demands are supported by a peak high-overload current of 125 A, while normal-duty transients are limited to 110 A. Each surge is time-limited by the drive’s thermal protection model to prevent excessive stress on the power stage and connected motor. Apparent power reaches 82.7 kVA during high-overload operation and 99.6 kVA in the normal-duty profile, providing useful values for transformer selection and cable ampacity calculations. The high-overload profile supports applications that experience greater torque demand during acceleration or changing hydraulic conditions. The normal-duty profile is suited to pump systems with smoother load characteristics and a higher continuous power requirement. These operating modes allow the drive to regulate submersible or surface-mounted pump motors connected to constant 575 V industrial feeders.

Efficiency
0.98
Estimated Power Loss
1500 W
High Overload Continuous Current
83 A
High Overload Input Current At 575 V
75 A
High Overload Intermittent Current
125 A
High Overload Kva At 575 V
82.7 kVA
High Overload Power
55 kW
Maximum Ambient Temp
50 °C
Maximum Pre-fuse
225 A
Maximum Shielded Motor Cable
150 m
Normal Overload Continuous Current
100 A
Normal Overload Input Current At 575 V
91 A
Normal Overload Intermittent Current
110 A
Normal Overload Kva At 575 V
99.6 kVA
Normal Overload Power
75 kW
Power Phase
Three Phase Power
Product Group
VLT AQUA Drive
Series Identifier
202

Frequently Asked Questions about FC-202P75KT6134F4379:

Q: What is the efficiency rating of the Danfoss FC-202P75KT6134F4379 drive?

A: The FC-202P75KT6134F4379 offers a power efficiency of 0.98, ensuring minimal energy loss during operation.

Q: What is the normal overload continuous current rating of this VLT AQUA Drive?

A: The FC-202P75KT6134F4379 can handle a normal overload continuous current of 100 A, suitable for demanding motor control applications.

Q: What is the maximum allowable length for shielded motor cabling on the FC-202P75KT6134F4379?

A: This model supports a maximum shielded motor cable length of up to 150 meters.

Q: What is the highest ambient temperature the FC-202P75KT6134F4379 can function in?

A: The drive can operate in environments with ambient temperatures up to 50 °C.

Q: What is the recommended maximum pre-fuse size for this Danfoss VLT FC 202 drive?

A: A maximum pre-fuse rating of 225 A should be used with the FC-202P75KT6134F4379 to ensure proper protection.


Internal Product Review