FC-202P75KT4131F1079 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P75KT4131F1079 is part of the VLT FC 202 AQUA Drives series and provides a power rating of 75 kW (100 hp) with an efficiency of 0.98. It operates on three phase power at 380 to 480 VAC and has an output current of 130 Amps. The drive supports shielded motor cables up to 150 meters and can be used at an altitude of up to 1000 meters without derating.
Internal Product Review
The FC-202P75KT4131F1079 is a Danfoss VLT FC 202 AQUA drive with a 75 kW power rating for 380 to 480 VAC systems. Efficiency of 0.98 and output current of 130 A support dependable speed control and strong electrical performance in pump-duty service. Unshielded motor cable capability up to 300 m makes the unit especially well suited for extended installation runs.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P75KT4131F1079 is an AC variable-frequency drive produced by Danfoss and assigned to the VLT FC 202 AQUA Drives series. Designed for pump and fan duties, the unit modulates motor speed to match real-time flow or pressure requirements in water and wastewater automation. By converting three-phase mains power into a controlled output waveform, it supports energy savings and smooth starts while maintaining compatibility with the broader VLT AQUA Drive product group.
The drive accepts a supply window of 380 - 480 VAC, drawing 118 A at its rated operating point. Through its insulated-gate converters, it provides 130 A of phase-balanced output current, producing up to 103.6 kVA of apparent power for the connected motor. The power section is sized for a continuous mechanical delivery of 75 kW, equivalent to 100 horsepower, allowing centrifugal pumps to maintain high flow without external step-up gearboxes. Voltage, current, and power ratings inform feeder breaker sizing, cable cross-section, and enclosure ventilation, ensuring that upstream protection devices and heat sinks remain within their allowable temperature rise during constant-torque or quadratic-torque duty cycles.
Additional limits define safe field installation. The control permits an overload of 143 A for short acceleration bursts, and total drive losses remain at 1500 W when running at the catalog efficiency of 0.98. Ambient operation is allowed up to 50 °C and to altitudes of 1000 m without derating; sites up to 3000 m require current reduction. Humidity can reach 95% non-condensing, supporting placement in pump rooms or filter galleries. Motor leads may extend to 150 m when shielded, doubling to 300 m for unshielded cable, so the electronics can stay outside splash zones while still controlling submerged or remote pump assemblies.