FC-202P75KT4131B9070 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P75KT4131B9070 is part of the VLT FC 202 AQUA Drives series and operates on three phase power with a mains voltage of 380 to 480 VAC. It supports continuous input currents of 133 A at 380-440 V and 118 A at 441-480 V, while providing continuous output currents of 147 A and 130 A in those respective voltage ranges. This drive achieves an energy efficiency class of IE2 and allows for a maximum ambient temperature of 50 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P75KT4131B9070 is a Danfoss AC variable-frequency drive supplied in the VLT FC 202 AQUA Drives series. As part of the VLT AQUA Drive product group, it controls induction-motor speed for pumps, blowers, and other water-handling equipment. The drive transforms the plant’s mains supply into a variable output that follows process demand.
Under 380–440 V operation, the converter draws 133 A and can supply a continuous motor current of 147 A. When the line rises to 441–480 V, the input requirement falls to 118 A, while the drive still delivers 130 A to the load. The power section sustains 102 kVA at 400 V, so upstream conductors and the recommended 250 A prefuses must be sized accordingly. Control electronics accept 24 V logic and protect field wiring with a digital-input ceiling of 28 V DC, while transistorized outputs can pulse feedback or relay commands at frequencies up to 32 kHz. The analog feedback channel supports loads down to 500 Ω. Power enters through three-phase 380–480 VAC mains, and the unit meets the IE2 energy-efficiency class, minimizing distribution losses in continuous-duty installations.
Brake wiring can have a cross-sectional area of up to 95 mm², while line and motor terminals accept copper conductors with a cross-sectional area of up to 150 mm². Shielded motor leads may extend to 150 m, or 300 m when unshielded, without exceeding switching constraints. Internal logic reacts within 2 ms or less to setpoint changes, supporting responsive control as operating demand varies. Reliable operation continues at ambient temperatures up to 50 °C, matching conditions found in typical utility rooms. The conductor limits provide sufficient capacity for the drive’s power connections without requiring parallel cables in many installations.