FC-202P75KT4131B9066 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P75KT4131B9066 is part of the VLT FC 202 AQUA Drives series and is designed for use with three phase power at 380 to 480 VAC mains voltage. It offers a rated power of 75 kW and has a maximum continuous output current of 130 A at 441 to 480 V. This drive achieves an efficiency of 0.98 and an energy class rating of IE2.
Internal Product Review
The FC-202P75KT4131B9066 is a Danfoss VLT FC 202 AQUA drive rated at 75 kW for three-phase power applications. Operation on 380–480 VAC mains with 0.98 efficiency gives the drive excellent energy performance for demanding pump and water system duty.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P75KT4131B9066 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It is intended for speed-controlled pump and blower applications in water and wastewater facilities, where it adjusts the speed of three-phase induction motors according to changing process demands. This control method helps maintain stable flow or pressure while reducing the energy consumed by equipment that would otherwise operate continuously at full speed.
This model delivers a rated output of 75 kW and accepts a three-phase supply of 380–480 VAC. At full load, the inverter reaches an efficiency of 0.98, supporting its IE2 energy class. Continuous output current on 441–480 V grids is 130 A, while the maximum input current is limited to 118 A. A process-standard analog output provides a range of 0/4–20 mA for connection to compatible instrumentation and control equipment. Digital control inputs operate from 0–24 V DC, allowing the drive to receive switching commands from a PLC or related automation device. Output frequency is generated with a resolution of ±0.003 Hz, enabling precise regulation of centrifugal pump and blower speeds during process changes.
Continuous operation is permitted at ambient temperatures from 0 °C through 50 °C. The drive maintains its full current capability at elevations of up to 1000 m without derating, which supports installation in facilities located above sea level. Short-circuit protection requires an upstream 250 A semiconductor fuse to protect the feeder and power electronics during fault conditions. Installations may use shielded motor cables up to 150 m long to help control conducted electromagnetic emissions. When electromagnetic shielding is not required, unshielded motor cable runs may extend up to 300 m without additional output filters. These cable allowances provide flexibility when the drive and motor must be installed in separate areas of a pump station or treatment facility.