FC-202P75KT Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P75KT belongs to the VLT FC 202 AQUA Drives series and features a power rating of 75 kW with support for 100 horsepower. This drive operates on three phase power with a supply frequency of 50/60 Hz and can handle a maximum output voltage equal to the supply voltage. It includes one analog output with 8-bit resolution and two digital or pulse outputs, and works at ambient temperatures up to 50 degrees Celsius.
Internal Product Review
The FC-202P75KT is a Danfoss VLT FC 202 AQUA Drive with a 75 kW power rating and three-phase power input. Stable electrical performance from a true power factor of ≥0.9 and reliable operation up to 50 °C make this drive a strong choice for demanding pump and fan systems.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P75KT variable frequency drive is produced by Danfoss as part of the VLT FC 202 AQUA Drives series. The unit converts fixed-frequency, three-phase power into a controlled output that allows automation systems to adjust pump and fan speeds in water processing, irrigation, and HVAC installations. This speed control lets the connected equipment balance flow against demand while reducing unnecessary energy use. Pump-specific control algorithms support common water-management functions and help maintain stable operation as process conditions change.
The drive can deliver up to 75 kW to the motor terminals as its maximum continuous output without derating. It is intended for three-phase power grids and accepts source frequencies of 50/60 Hz, +4%/-6%, allowing operation with either common utility frequency. The input tolerates a maximum supply voltage imbalance of 3.0%, helping the DC link remain stable under normal operating conditions. An internal rectifier maintains a true displacement power factor of at least 0.9 under nominal load. One analog output with eight-bit resolution and two digital or pulse outputs provide scaled speed or flow feedback to connected control systems. The inverter can hold its synthesized output voltage at the full supply level. Automatic restarts are limited to one per minute to reduce stress on the precharge components.
The drive can operate from 0 °C up to an ambient temperature of 50 °C when installed at or below an altitude of 1000 m. Above that altitude, the maximum current is reduced to keep semiconductor junction temperatures within permissible limits. The inverter supports shielded motor cables up to 150 m long, providing flexibility when pumps are located away from the drive enclosure. Unshielded motor cables can extend up to 300 m where the installation permits their use. Onboard diagnostics record thermal events, allowing operating history to be reviewed when abnormal temperature conditions occur. Appropriate enclosure ventilation and cable routing help the drive remain within its operating limits during continuous pump or fan service.