FC-202P5K5T6134U9699 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P5K5T6134U9699 is part of the VLT FC 202 AQUA Drives series and is designed for three phase power. It has a power rating of 5.5 kW, delivers 7.5 horsepower, and supports a maximum continuous output current of 9.5 A at 525-550 V. The drive offers 0.97 efficiency and can operate without derating up to 1000 meters altitude.
Internal Product Review
The FC-202P5K5T6134U9699 is a Danfoss VLT FC 202 AQUA drive rated for 5.5 kW on three-phase power. Technical performance is impressive, with 0.97 efficiency and 9.5 A continuous output current at 525-550 V supporting dependable process control. A 50 °C maximum ambient rating and 150 m shielded motor cable capability make the drive a very capable choice for demanding water-handling applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P5K5T6134U9699 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. In pumping and water-treatment systems, it adjusts the speed of three-phase induction motors to match real-time flow or pressure demand, reducing energy consumption and mechanical wear. The drive accepts three-phase input power and regulates motor output according to process requirements. Input power is protected by a gG-16 fuse, while the maximum upstream fuse rating is 32 A.
This model delivers a rated shaft power of 5.5 kW, equivalent to 7.5 HP, and its DC link and output stage can provide 9.0 kVA of continuous apparent power at 550 V. When supplied by 525–550 V mains, the inverter provides 9.5 A of motor current; the available current changes to 9.0 A when the supply is between 551 and 600 V. Its conversion efficiency reaches 0.97, limiting heat loss to 195 W at rated load. The control electronics permit two power-ups per minute to reduce capacitor stress during rapid cycling. This restriction should be considered when external controls repeatedly disconnect and restore input power.
The input side draws 8.6 A at full load, and the drive can operate without thermal derating at altitudes up to 1000 m. The monitored ambient temperature may reach 50 °C before the drive begins reducing its output. Shielded motor cables may be up to 150 m long, supporting installations in which pumps are located away from the control enclosure. The spring terminals accept conductor cross sections up to 4 mm², or up to 6 mm² when single-core disconnect wiring is used. The input choke has a voltage drop equal to 9% of the nameplate voltage and helps mitigate harmonics. Dedicated protective-earth clamps maintain cable armor continuity throughout the installation.