FC-202P5K5T6131Z9028 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P5K5T6131Z9028 is part of the VLT FC 202 AQUA Drives series, offering a power rating of 5.5 kW and 7.5 HP for three phase power systems. It operates at supply voltages from 525 to 600 V AC and can supply a continuous output current of 9.5 Amps at 525-550 V. The drive achieves an efficiency of 0.97 and is rated for use at altitudes up to 1000 meters and maximum ambient temperatures of 50 degrees Celsius.
Internal Product Review
The FC-202P5K5T6131Z9028 is a Danfoss VLT FC 202 AQUA drive with a 5.5 kW power rating and three-phase power input. Operation is notably efficient, with 0.97 efficiency and an IE2 energy class supporting dependable performance in water and pumping applications. A strong choice for stable and economical variable speed control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P5K5T6131Z9028 variable-frequency drive is produced by Danfoss for the VLT FC 202 AQUA Drives series. It is designed for three-phase pump and fan motors in water and wastewater facilities, where precise speed regulation lowers power consumption and reduces hydraulic shock during startup and shutdown. The unit is classified in energy class IE2, confirming that its no-load and partial-load losses meet the efficiency baseline for variable-speed drives in pump applications.
The drive’s power section is rated at 5.5 kW, which is the maximum continuous mechanical power it can deliver to a connected motor. This output corresponds to 7.5 HP. At a supply range of 525–550 V, the inverter can provide a continuous current of 9.5 A, so cable sizing and overload protection must match this output. Its intermediate DC link and IGBT stage support a continuous apparent power of 9.0 kVA; this value indicates the total volt-ampere load presented to upstream feeders. Overall conversion efficiency reaches 0.97, meaning only three percent of incoming energy is lost as heat under nominal load. Thermal dissipation is indicated by a rated power loss of 195 W, which guides enclosure ventilation and heat-sink requirements.
Operation is permitted up to 1000 m above sea level without derating, so standard performance is maintained at most plant elevations. The electronics tolerate ambient temperatures as high as 50 °C, provided cabinet airflow prevents hot spots from forming around the heat sink. Motor leads may extend up to 150 m, allowing remote pump sets to be controlled without installing local drives. Additional wiring parameters include a maximum motor cable cross-section of 4 mm², a disconnect requirement of 6 mm², and a prefuse limit of 32 A. These values establish clear boundaries for conductor selection and upstream protection.