FC-202P5K5T4131F7943 FC202P5K5T4131F7943 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P5K5T4131F7943 FC202P5K5T4131F7943 is part of the VLT FC 202 AQUA Drives series and is rated for three phase power with a power rating of 5.5 kW and 7.5 HP. It operates at mains voltages from 380 to 480 VAC with a continuous output current of 13 A and energy efficiency class IE2. The drive achieves an efficiency of 0.97 and is designed for a maximum ambient temperature of 50°C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P5K5T4131F7943 FC202P5K5T4131F7943 is an AC variable frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. The unit converts fixed-frequency, three-phase mains power into a regulated output that allows automation controllers to adjust pump or fan speed in water-handling systems. Electronic torque control reduces mechanical stress on connected equipment during starting, stopping, and changes in process demand. Variable-speed operation also lowers energy consumption when the system requires less than the motor’s full output while maintaining the required pressure or flow.
The drive delivers a continuous output current of 13 A when supplied from 380–440 V, and its intermittent capacity rises to 19.5 A for short acceleration periods. The input accepts 380–480 VAC from a three-phase network, allowing the model to operate with several common industrial supply voltages. At its 5.5 kW power rating, the drive has an efficiency of 0.97 and an estimated thermal loss of 187 W, supporting its IE2 efficiency classification. Its built-in motor power rating is 7.5 HP, which supports matching the drive to an appropriately sized motor. Line demand remains within a maximum input current of 11.7 A, allowing the supply conductors and protective equipment to be selected accordingly. The drive tolerates a phase imbalance of 3 percent. Its ramp time can be adjusted up to 3,600 seconds to provide smooth acceleration for systems with high inertia or pressure-sensitive piping.
The drive can be installed at elevations up to 1000 m without output derating, preserving its available motor current at the stated altitude. It maintains full thermal capacity at ambient temperatures up to 50 °C, provided that the installation allows adequate airflow around the enclosure. Motor leads may extend to 150 m when shielded cable is used, while unshielded cable permits a maximum length of 300 m for remote pump installations. Circuit protection can use a maximum upstream fuse of 30 A to coordinate fault protection with the drive’s input stage. The control logic limits energization to two starts per minute, helping protect the DC-link components from repeated charging cycles.