FC-202P55KT6131N7825 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The FC-202P55KT6131N7825 is a VLT FC 202 AQUA Drive from Danfoss with a shaft output power of 55 kW and an efficiency of 0.98. This drive supports a continuous input current of 75 Amps and a continuous output current of 83 Amps on three phase power. It is rated for a maximum ambient temperature of 50°C and supports motor cables up to 150 meters shielded or 300 meters unshielded.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P55KT6131N7825 is an AC variable frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. Intended for centrifugal pumps and blowers, the unit converts fixed mains frequency into a pulse-width-modulated output, allowing process controllers to adjust motor speed accurately. This capability saves energy, minimizes hydraulic shocks, and extends equipment life in municipal and industrial water systems.
Its shaft output is rated at 55 kW, indicating the maximum continuous mechanical power available to a connected induction motor at nominal voltage and frequency. Upstream conductors must accommodate a continuous input current of 75 A, while downstream motor leads must carry up to 83 A without excessive voltage drop. An efficiency of 0.98 indicates that losses are limited to approximately 1.1 kW, simplifying thermal management inside a control cabinet. The drive maintains these values while operating from a three-phase power supply. Its components remain within thermal limits when the surrounding air temperature does not exceed 50 °C.
For short-duration overloads, the inverter can deliver 91 A, enabling quick acceleration or helping clear pipeline blockages without requiring an oversized motor. Supply protection is coordinated through a maximum upstream fuse rating of 160 A, ensuring fault currents are interrupted before semiconductor damage occurs. The overall design meets the IE2 efficiency target, supporting compliance with applicable regional energy requirements. The power stage supports an unshielded motor cable run of up to 300 m, allowing the drive to remain in a dry electrical room while the motor operates in the field. With 15 m motor leads, the output has a rise time of 0.276 µs and a peak voltage of 1.184 kV. When rapid deceleration is required, the external braking resistor must have a minimum resistance of 11.7 Ω, while its nominal resistance is 15.8 Ω.