Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P55KT6131G2017 is part of the VLT FC 202 AQUA Drives series and operates with a supply voltage range of 525 to 600 V AC and a shaft output of 55 kW. This three phase drive has a maximum ambient temperature of 50 °C, runs at an efficiency of 0.98, and features a continuous output current of 83 A.
Internal Product Review
The FC-202P55KT6131G2017 is a Danfoss VLT FC 202 AQUA drive that delivers 55 kW shaft output and supports three-phase power operation. High conversion quality shows in 0.98 efficiency and a displacement power factor above 0.98, which supports stable performance under load. The 0–590 Hz output frequency gives the drive impressive control range for precise variable-speed applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P55KT6131G2017 is a variable frequency drive manufactured by Danfoss and supplied within the VLT FC 202 AQUA Drives series. Designed for pump and fan regulation in water and wastewater systems, the unit modulates motor speed by converting fixed mains power into a controlled output waveform. By adjusting frequency and voltage to match load demand, the drive helps maintain constant pressure or flow while lowering energy consumption and mechanical stress on connected induction motors used in industrial automation.
The drive accepts a three-phase supply of 525–600 V AC ±10% at a frequency of 50 or 60 Hz, with a tolerance of +4% to -6%, and delivers an output voltage ranging from 0% to 100% of the input voltage. Nominal shaft power reaches 55 kW, while the high-overload rating provides 45 kW for applications that need additional starting torque. Continuous apparent power at 575 V is 82.7 kVA, supported by a continuous output current of 83 A. The output frequency can be set between 0–590 Hz for precise flow control. Electrical efficiency is 0.98, and the drive generates 1100 W of heat at rated load, which must be removed from the enclosure to keep semiconductor temperatures within operating limits. The true power factor is at least 0.9, indicating minimal reactive current drawn from the mains.
The maximum input current drawn at 575 V is 75 A, so Danfoss recommends a 160 A pre-fuse to clear fault currents rapidly. Shielded motor leads can run up to 150 m without violating drive switching limits, enabling remote pump placement. Ambient operation is permitted up to 50 °C; above that temperature, output derating applies. The displacement power factor is greater than 0.98, helping facilities meet utility harmonic guidelines. Upstream protective devices must be selected to accommodate the available fault current and the drive’s maximum input demand.