★★★★★
4.94 based on 222 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

FC-202P55KT4131H3750 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-202P55KT4131H3750 is part of the VLT FC 202 AQUA Drives series and delivers a rated power of 55 kW with a continuous output current of 105 A. It features an efficiency of 0.98 and operates on mains voltages between 380 and 480 VAC three-phase power. This drive includes one programmable analog output, two digital pulse outputs, and an RFI filter classified as Class A1/B (C1).

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202P55KT4131H3750 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It modulates the speed of three-phase induction motors used in pumping and aeration systems. This speed control allows motor output to match real-time flow or pressure demand while reducing energy consumption and mechanical stress on pipelines and impellers.

The drive supplies up to 55 kW of continuous motor output and delivers a motor-side current of 105 A. On the line side, it draws 95 A, and its internal power section converts the incoming 380–480 VAC mains power into a pulse-width modulated waveform. Total drive efficiency is 0.98, helping limit electrical losses during continuous operation. A continuous apparent-power rating of 83.7 kVA at 460 V supports transformer and supply sizing. The three-phase input topology is compatible with standard industrial power distribution networks. The unit includes an RFI Class A1/B (C1) filter to control conducted emissions, and its terminals accept motor and line conductors with cross-sectional areas up to 50 mm². These power terminals accommodate the larger conductors commonly required for high-current pump and aeration motors.

The control terminal block provides one programmable analog output that can drive a load of up to 500 Ω. This channel has an 8-bit resolution and can transmit proportional feedback to valves, meters, or supervisory control equipment. Digital inputs tolerate 28 V DC and present an impedance of 4 kΩ to connected PLC cards. The corresponding transistor output switches at up to 32 kHz, supporting high-speed pulse signals used for flow metering. Two digital pulse outputs can transmit operating status, accumulated runtime, or fault information, while the analog channel supports legacy 0–10 V signaling. Branch-circuit protection can use the recommended 160 A maximum pre-fuse value to coordinate the drive with upstream protective devices. Heat dissipation at rated load is 1100 W, allowing cabinet airflow and cooling capacity to be planned for constant-torque pump operation. The published thermal loss also helps maintain the inverter within its permitted operating temperature when installed in an enclosure.

Analog Output Max Load
500 Ω
Analog Output Resolution
8 bit
Continuous Input Current
95 A
Continuous Kva At 460 V
83.7 kVA
Continuous Output Current
105 A
Digital Input Max Voltage
28 V DC
Digital Input Resistance
4 kΩ
Digital Output Max Freq
32 kHz
Digital Pulse Outputs
2
Efficiency
0.98
Mains Voltage
380 - 480 VAC
Max Line/motor Cable
50 mm²
Max Pre-fuse
160 A
Power Loss At Rated Load
1100 W
Power Phase
Three Phase Power
Product Group
VLT AQUA Drive
Programmable Analog Outputs
1
Rated Power
55 kW
RFI Filter
RFI Class A1/B (C1)
Series Identifier
202

Frequently Asked Questions about FC-202P55KT4131H3750:

Q: What is the mains voltage range for the FC-202P55KT4131H3750 drive?

A: The FC-202P55KT4131H3750 operates with a mains voltage range of 380 to 480 VAC, making it compatible with standard industrial power supplies.

Q: What is the continuous output current of the FC-202P55KT4131H3750?

A: This model has a continuous output current rating of 105 A, suitable for driving large loads.

Q: What is the rated power of the FC-202P55KT4131H3750 drive?

A: The rated power for the FC-202P55KT4131H3750 is 55 kW, making it ideal for substantial pump and fan operations.

Q: What type of RFI filter is included with the FC-202P55KT4131H3750?

A: The FC-202P55KT4131H3750 features an RFI filter rated at Class A1/B (C1), supporting electromagnetic compatibility in sensitive environments.

Q: What is the power loss at rated load for the FC-202P55KT4131H3750?

A: At rated load, power loss for the FC-202P55KT4131H3750 drive is 1100 W, which should be considered for thermal management.


Internal Product Review

  • ‘‘The FC-202P55KT4131H3750 is a Danfoss VLT AQUA drive rated for 55 kW on 380 - 480 VAC systems. Three-phase power architecture and 0.98 efficiency support stable, energy-conscious motor control in water and process applications. Continuous output current of 105 A gives the drive strong operating headroom, making the unit a very capable choice for demanding AQUA installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo