FC-202P55KT4131B9056 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P55KT4131B9056 is part of the VLT FC 202 AQUA Drives series and operates on a three phase power supply with a mains voltage of 380 to 480 VAC. This drive offers a typical shaft output of 55 kW and a continuous output current of 105 Amps at 480 V. Its efficiency is 0.98, and it can handle a maximum input current of 95 Amps at 480 V.
Internal Product Review
The FC-202P55KT4131B9056 is a Danfoss VLT FC 202 AQUA Drive designed for process pumping systems, with 55 kW typical shaft output and 380 - 480 VAC operation. A 0.98 efficiency rating and 105 A continuous output current support efficient power conversion and steady motor control under load. A very capable drive for high-demand AQUA installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P55KT4131B9056 variable frequency drive is built by Danfoss within the VLT FC 202 AQUA Drives series. It is intended for centrifugal pump, blower, and aerator duties where precise speed regulation reduces mechanical stress and supports stable process control. By adjusting the motor frequency, it supplies only the torque demanded by the process and allows direct integration in industrial automation architectures that supervise flow or pressure across treatment, irrigation, and filtration lines.
On the power side, the drive operates on three-phase mains from 380 to 480 VAC and delivers a continuous apparent power of 83.7 kVA. At 480 V, it supplies a continuous motor current of 105 A, while the incoming line is limited to 95 A to keep upstream components within rating. A full-load efficiency of 0.98 converts almost all electrical power into motion, giving a typical shaft output of 55 kW for pumps and blowers. The inverter switching stage is dimensioned for this drive class and is protected by a 160 A semiconductor fuse that clears faults before damage occurs.
In control applications, the low-level interfaces are sized to match typical sensor and actuator requirements. The analog outputs have an error band of 0.8% of full scale, drive a 500 Ω load, and use 8-bit resolution, which is adequate for valve positioning or speed feedback signals. Digital I/O is likewise isolated; inputs tolerate up to 28 V DC, while each transistor output can source 40 mA at frequencies up to 32 kHz for pulse-train flow meters. For field installation, the inverter supports shielded motor leads up to 150 m so the cabinet can be placed remote from wet areas. Internal losses are limited to 1083 W, and the heat sink maintains performance up to 50 °C ambient for continuous service in pump rooms.