FC-202P4K0T6134L6301 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P4K0T6134L6301 is part of the VLT FC 202 AQUA Drives series and supports three-phase power with a power rating of 4.0 kW and 5.0 HP. It features an output current of 6.4 A at 550 V, delivers efficiency of 0.97, and belongs to the IE2 energy efficiency class. The drive allows a maximum ambient temperature of 50 °C and supports up to 300 meters of unshielded motor cable.
Internal Product Review
The FC-202P4K0T6134L6301 is a Danfoss VLT FC 202 AQUA drive rated for 4.0 kW and 5.0 HP. High efficiency at 0.97 and a displacement power factor above 0.98 give the drive impressive electrical performance in pump and fan service. Motor cable capability up to 150 m shielded and 300 m unshielded adds valuable installation flexibility.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P4K0T6134L6301 is an AC variable-frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. It modulates the speed of three-phase induction motors that power pumps, aerators, and blowers in water and wastewater facilities, allowing control systems to match flow or pressure to real-time demand and reduce energy consumption. By replacing mechanical throttling with electronic torque regulation, the unit supports tighter process control while protecting motors from electrical and hydraulic transients.
When supplied from a 550 V source, the inverter delivers up to 4.0 kW of shaft power and supplies an output current of 6.4 A. The input section draws a maximum of 5.8 A and has an apparent power rating of 6.1 kVA, which supports circuit breaker sizing and feeder selection. Overall conversion efficiency is 0.97, placing the product in the IE2 energy-efficiency class for drives. The three-phase topology and vector control maintain constant torque across the pump curve, while a 20 A prefuse coordinates short-circuit protection with upstream switchgear. Internal thermal management allows continuous operation without auxiliary cooling in most indoor enclosures.
Power quality remains high because the displacement power factor stays above 0.98, while the true power factor is at least 0.9 to minimize reactive load on the utility. The drive operates at ambient temperatures up to 50 °C without derating, aided by coated electronics and controlled airflow. Heat loss is limited to 145 W, reducing cabinet ventilation requirements. Motor terminals accept copper conductors up to 4 mm², and shielded output leads may extend to 150 m while meeting electromagnetic compatibility limits. Unshielded output cable may extend to 300 m. The input accommodates a disconnect device with conductors up to 6 mm², supporting installation in municipal or industrial pump stations.