FC-202P3K7T2134F8245 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P3K7T2134F8245 is part of the VLT FC 202 AQUA Drives series and operates on a three phase power supply with a mains voltage of 200 to 240 VAC. It has a shaft output of 3.7 kW, continuous output current of 16.7 Amps, and a maximum output frequency of 590 Hz. The drive provides an efficiency of 0.96 and supports a max ambient temperature of 50 degrees Celsius.
Internal Product Review
The FC-202P3K7T2134F8245 is a Danfoss VLT FC 202 AQUA Drive built for dependable three-phase motor control on 200 to 240 VAC input. Efficiency at 0.96 and continuous output current of 16.7 A support stable operation with strong energy performance in water-handling systems. A maximum output frequency of 590 Hz stands out as a valuable performance advantage.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P3K7T2134F8245 is an AC variable-frequency drive built by Danfoss within the VLT FC 202 AQUA Drives series. It belongs to the VLT AQUA Drive product group and is designed to regulate induction motor speed in pumping and aeration equipment used across water and wastewater facilities. By converting a fixed three-phase 200–240 VAC supply into a controllable output, the drive allows process controllers to match motor torque to real-time flow requirements and reduce energy consumption. This variable-speed operation helps prevent pumps from running continuously at full output when process demand is lower.
Under continuous load, the inverter delivers 6.00 kVA of apparent power and supplies a steady output current of 16.7 A. Electrical efficiency reaches 0.96, so only a small portion of the input energy is dissipated as heat. The resulting power loss is 185 W, which must be considered when providing panel ventilation. The control section can raise the fundamental frequency to 590 Hz, providing sufficient range for high-speed pump applications. Rated operation is supported on utility grids operating at either 50 Hz or 60 Hz. Continuous performance is maintained throughout the supported input voltage range.
The maximum incoming line current is 15.0 A, and a supply imbalance limit of 3.0% helps protect the rectifier section and associated semiconductors. Upstream circuit protection is provided by a 32 A fuse, and the drive supplies a shaft output of 3.7 kW for midrange centrifugal pumps. The thermal design permits operation at ambient temperatures up to 50 °C without derating. Shielded motor cables can extend up to 150 m, supporting installations with motors located away from the control panel. Control terminals accept conductors with cross-sectional areas up to 6 mm², while the line and motor terminals accommodate conductors up to 4 mm². These conductor capacities allow appropriately sized wiring to be connected directly to the designated terminals.