FC-202P3K7T2131Z1398 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P3K7T2131Z1398 is part of the VLT FC 202 AQUA Drives series and provides a typical shaft output of 3.7 kW with an energy efficiency class of IE2. This drive operates with three phase power at 200 to 240 VAC and offers a continuous output current of 16.7 A. It is rated for up to 50 degrees Celsius maximum ambient temperature and allows for a maximum altitude of 1000 meters without derating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P3K7T2131Z1398 is a variable-frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. The unit converts three-phase mains power into a modulated output for pumps and blowers in water-handling systems. It adjusts motor torque and speed to support automated flow regulation and reduce energy use in treatment plants and distribution networks.
The drive delivers a continuous output current of 16.7 A, matching its 3.7 kW shaft rating to typical 200–240 V induction motors. Electrical efficiency reaches 0.96, and the drive is classified in the high-performance IE2 efficiency class, so less energy is wasted as heat. Under nominal load, the electronics dissipate only 185 W, which simplifies enclosure cooling. The input stage accepts a line voltage range of 200–240 VAC and draws 15.0 A continuously while presenting a demand of 6.00 kVA at 208 V. A 32 A pre-fuse provides upstream protection, and the three-phase topology supports balanced loading on low-voltage distribution networks. The maximum relative humidity is 95%, allowing placement in humid pump rooms. The drive also withstands 1.0 g of vibration, helping it maintain consistent operation on wall or skid mounts.
The drive can operate at altitudes up to 1000 m without derating and within a temperature range of 0 °C to 50 °C. Power conductors with a maximum cross-sectional area of 4 mm² can be connected to the terminals, and shielded motor cables may extend up to 150 m while meeting applicable electromagnetic compatibility requirements for AQUA applications. Below 0 °C, the internal sensors may no longer maintain full-scale accuracy, so the stated operating range should be observed when selecting the mounting location. Adequate cabinet ventilation is required at the highest permitted ambient temperature to remove heat generated during operation.