FC-202P3K7T2131H8714 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P3K7T2131H8714 is part of the VLT FC 202 AQUA Drives series and operates on a mains voltage of 200 to 240 VAC with three phase power. This drive has a typical shaft output of 3.7 kW, continuous output current of 16.7 Amps, and an efficiency of 0.96. It is rated for ambient temperatures up to 50 °C and supports shielded motor cables up to 150 meters.
Internal Product Review
The FC-202P3K7T2131H8714 is a Danfoss VLT FC 202 AQUA drive for three-phase 200-240 VAC systems. A 0.96 efficiency rating and 16.7 A continuous output current give the unit a very well-balanced operating profile for demanding pump installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P3K7T2131H8714 is a Danfoss AC variable-frequency converter in the VLT FC 202 AQUA Drives series and the VLT AQUA Drive product group. It accepts three-phase mains power and generates a controlled output waveform for precise speed regulation of standard induction motors used in industrial automation. The converter uses series identifier 202 and adjusts motor speed to match load demand, which can reduce electrical consumption during continuous service. Its variable-frequency output is suitable for applications that require controlled acceleration, deceleration, and steady operation under changing process conditions.
The inverter delivers a typical shaft output of 3.7 kW, supported by a continuous output current of 16.7 A and a 208 V apparent power rating of 6.00 kVA. It is intended for a 200–240 VAC three-phase power supply, and a line-side fuse rated up to 32 A protects the input circuit. Conversion efficiency reaches 0.96, so the full-load power loss of 185 W must be dissipated as heat, and the unit meets the IE2 energy-efficiency class. Electronic components can operate at a maximum ambient temperature of 50 °C. Control terminals provide an analog output that can drive 500 Ω loads for process feedback, while a digital output supplies up to 40 mA for status signaling. Shielded motor cables may extend up to 150 m, while unshielded cables may extend up to 300 m, simplifying installation in distributed equipment rooms.
No derating is required at elevations up to 1000 m, allowing standard performance in most facilities. The input section supports a maximum supply current of 15.0 A, and an internal C2-class radio-frequency interference network rated as RFI C2 limits conducted emissions on the mains. Field wiring accommodates conductors up to 4 mm², and the drive can energize the motor through these cables while remaining within its continuous apparent power rating. The analog and digital control outputs support connections to external monitoring and status circuits. Available motor-cable distances also provide flexibility when the converter and motor are installed in separate areas.