FC-202P3K0S2134F6384 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P3K0S2134F6384 is part of the VLT FC 202 AQUA Drives series and has a power rating of 3.0 kW and an efficiency of 0.98. It operates on a mains voltage between 200 and 240 VAC with a continuous input current of 24 A. The drive supports single-phase power, delivers a maximum output of 4.0 HP, and allows for a maximum ambient temperature of 50 °C.
Internal Product Review
The FC-202P3K0S2134F6384 is a Danfoss VLT FC 202 AQUA drive engineered for dependable fluid-handling applications, with a 3.0 kW power rating and 200 - 240 VAC mains voltage. High efficiency of 0.98 and normal overload capacity of 110% for 1 min support stable performance under changing load conditions. Installation flexibility is a notable strength, highlighted by support for 150 m shielded motor cable.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P3K0S2134F6384 is an AC variable frequency drive manufactured by Danfoss within the VLT FC 202 AQUA Drives series. As a stand-alone power converter, it regulates the speed of centrifugal pumps, blowers, and other water-handling machinery by adjusting the motor’s supply frequency. The unit connects directly to low-voltage utility lines and provides three-phase output tailored for fluid-process automation where energy savings and soft starting are critical.
The drive is rated for a mechanical output of 3.0 kW, which corresponds to 4.0 HP. It accepts a single-phase mains supply in the range of 200 to 240 VAC and converts this supply into three-phase power for the motor terminals. During continuous operation, the input stage draws 24 A, while the inverter supplies up to 12.5 A RMS to the load, permitting accurate sizing of upstream feeders and output conductors. Apparent power demand reaches 4.5 kVA at 208 V, so a 40 A prefuse protects the line side. A digital output carrier limit of 32 kHz supports low acoustic noise. Motor cables may be routed up to 150 m when shielded or 300 m when unshielded without retuning.
Short-term process peaks are handled by an overload capacity of 110% for 1 minute, allowing the drive to tolerate transient head increases without tripping. Energy conversion efficiency is 0.98, so approximately 60 W of power is dissipated as heat at full load, simplifying enclosure ventilation. Operation is allowed up to 1000 m above sea level without current derating; above this elevation, the output must be reduced. Additional limits include an ambient temperature ceiling of 50 °C and a motor-cable insulation temperature of 75 °C, both of which help prevent thermal degradation.