FC-202P37KT4131B9045 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P37KT4131B9045 is a 50 HP drive from the VLT FC 202 AQUA Drives series, offering a power rating of 37 kW and designed for three phase power at 380 to 480 VAC. It supports a maximum output frequency of 590 Hz, a displacement power factor greater than 0.98, and operates efficiently at altitudes up to 1000 meters with a maximum ambient temperature of 50 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P37KT4131B9045 is a variable frequency drive manufactured by Danfoss as part of the VLT FC 202 AQUA Drives series. Designed for centrifugal pumps, blowers, and similar loads in water treatment, it converts the fixed-frequency three-phase supply into a regulated output that maintains process pressure and flow. By integrating PID control and motor protection routines, the drive allows throttling valves to be replaced with electronic speed regulation, reducing energy use and extending mechanical service life.
Its nominal power rating is 37 kW, equivalent to 50 HP, so the unit can start and regulate medium-sized induction motors without external soft starters. The input section accepts three-phase mains from 380–480 VAC with a permitted phase imbalance of 3.0%, and it meets the IE2 energy-efficiency class used in modern installations. The displacement power factor remains above 0.98, while the true power factor remains at least 0.9. These values indicate that little reactive current is drawn, reducing upstream cable losses and transformer loading. The control logic also limits energization to one power-up per minute to protect the inrush-limiting resistors.
The inverter delivers up to 590 Hz at the motor terminals, enabling high-speed pump impellers when required for backwash or flushing cycles. Installation is permitted up to 1,000 m above sea level without derating, and continuous operation is allowed at ambient temperatures up to 50 °C as long as airflow around the heat sink is not obstructed. Conformal-coated circuit boards tolerate relative humidity up to 95%, so the unit can be mounted in damp valve pits if condensation is prevented. Output runs can use shielded cable up to 150 m or unshielded cable up to 300 m. A protective earth conductor of at least 10 mm² must be installed to carry fault current in accordance with applicable installation rules.