FC-202P30KT6134N2133 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The FC-202P30KT6134N2133 is a 40 HP drive from the VLT FC 202 AQUA Drives series by Danfoss. It operates on three phase power and has a power rating of 30 kW with an efficiency of 0.98. The drive provides an analog output range of 0/4-20 mA and supports an output current of 43 A at 525-550 V.
Internal Product Review
The FC-202P30KT6134N2133 is a Danfoss VLT AQUA drive built for demanding water and pump control, with a 30 kW rating and three-phase power input. Operation remains impressively efficient at 0.98 efficiency, and the 32 kHz maximum output frequency supports smooth motor control. This unit stands out as a capable 40 HP drive for high-performance process applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P30KT6134N2133 is an AC variable frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. Intended for pump and fan control in water-handling systems, it converts three-phase facility power into a modulated output that allows automation controllers to match motor speed to process demand. By adjusting output voltage and frequency, the drive can reduce energy consumption, stabilize flow, and limit mechanical stress on pipelines, impellers, and connected equipment.
With a 550 V supply, the drive delivers 41.0 kVA continuously and supports a motor output of 40 HP. Its conversion efficiency reaches 0.98, helping to limit heat generation during normal operation. Input current at this voltage is 39 A, while operation from a 575 V supply reduces the input current to 37 A. The control card provides a 0/4–20 mA analog feedback channel and accepts loads up to 500 Ω, allowing direct connection to compatible control devices. Pulse-width switching can be set as high as 32 kHz to reduce audible motor noise. An 80 A pre-fuse protects the rectifier section, and the drive provides a continuous capacity of 40.8 kVA when connected to a 575 V supply.
The inverter supplies an output current of 43 A when the output voltage is between 525 V and 550 V. A 60-second overload capacity of 47 A supports acceleration of high-inertia loads without requiring a larger drive. In the 551–600 V range, the continuous output current is 41 A, and the short-term limit is 45 A. Heat dissipation at full load is 600 W, and an internal fan assembly removes this heat from the power electronics. The power stage has a nominal output rating of 30 kW, making it suitable for variable-torque pump and fan applications. The adjustable output helps maintain process flow while reducing abrupt pressure changes during motor starts and stops.