FC-202P2K2T6131G2829 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P2K2T6131G2829 is part of the VLT FC 202 AQUA Drives series. This drive provides a power rating of 2.2 kW and operates with an efficiency of 0.97. It accepts a supply voltage from 525 to 600 V AC, supports three phase power, and delivers a maximum output current of 4.1 A.
Internal Product Review
The FC-202P2K2T6131G2829 is a Danfoss VLT FC 202 AQUA Drive built for precise variable frequency control in process pumping applications. A 2.2 kW power rating and 525–600 V AC supply range make the unit a strong fit for stable three-phase installations. High conversion quality is supported by 0.97 efficiency and output frequency capability to 590 Hz.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P2K2T6131G2829 variable frequency drive is built by Danfoss for the VLT FC 202 AQUA Drives series. It serves pump, blower, and filtration skids by adjusting motor speed to match real-time fluid demand, lowering energy use compared with direct-on-line operation. The drive connects to three-phase mains power and produces a synthesized AC waveform that keeps motor torque stable while maintaining process accuracy in water and wastewater installations.
Rated for an input range of 525–600 V AC, the converter draws a maximum input current of 4.1 A. The internal inverter stage can generate output frequencies from 0–590 Hz, so centrifugal pumps may run below or above synchronous speed as process conditions change. At 550 V, it supplies 4.1 A of motor current and provides a motor output of 3.0 HP, which corresponds to 2.2 kW. Overall efficiency reaches 0.97, and the true power factor remains at least 0.9, limiting reactive power draw from the supply network. The unit accepts a supply frequency of 50 or 60 Hz with a tolerance of +4% to -6%. Its digital inputs recognize 0–24 V DC signals for remote control and interlocks.
An analog feedback terminal provides a 0–20 mA or 4–20 mA range, allowing supervisory PLCs to monitor load or speed without additional transducers. Upstream protection is coordinated with a 20 A fuse, while the power section handles an apparent load of 3.9 kVA at rated voltage. Output voltage is regulated between 0% and 100% of the supply voltage regardless of the commanded frequency. The thermal design limits power dissipation to 92 W at full load. The converter uses a three-phase topology and accepts a supply-voltage tolerance of ±10%. Its supply-side power loss profile is optimized for continuous AQUA drive operation in pumping and water-treatment systems.