FC-202P2K2T6131G2829
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The FC-202P2K2T6131G2829 converter module by Danfoss, part of the VLT AQUA Drive FC 202 series, features an input voltage range of 525-600 VAC. It's equipped with electrically isolated interfaces, network capability, and delivers 2.2 kilowatts of shaft power. The module requires a separate TB712 terminal block for mounting.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P2K2T6131G2829 is a magnificent frequency converter masterfully created by the international company Danfoss. As part of the VLT automation drive series, the FC-202P2K2T6131G2829 features a 202 drive, six total digital inputs, and two analog inputs. Two out of the six digital inputs of the FC-202P2K2T6131G2829 may optionally be configured as digital outputs. For the single analog output of the FC-202P2K2T6131G2829 at terminal 42, the resolution is 8 bits. For frequency converters, the analog output terminal is usually connected to the three-phase motor. Without a connected three-phase motor, most of Danfoss’ frequency converters will prompt an error or warning message. Aside from the analog output, the FC-202P2K2T6131G2829 also supports up to two digital outputs.
The FC-202P2K2T6131G2829 has an efficiency of 97% and a usual shaft power of 2.2 kW or 3 hp. Like other FC-202 converters with a 2.2 kW output, the FC-202P2K2T6131G2829 can safely operate in normal and high overload modes to support a wide variety of applications and motors. At high-overload mode, the converter draws a maximum input current of 6.2 amperes. At this intermittent input current, the corresponding intermittent output current is around 5.9 to 6.2 amperes. At normal overload, the intermittent input and output currents are 4.5 A and 4.3 A, respectively.
At the rated load, the FC-202P2K2T6131G2829 achieves a true power factor and power loss of 0.9 and 35 watts, respectively. Depending on the enclosure, the converter’s mass, cable cross-section, and protection category may vary. At the default A3 enclosure, the FC-202P2K2T6131G2829 has a mass of 6.6 kilograms, a protection rating of IP 20, and a recommended cable cross-section of 3 x 12 AWG for motor, load sharing, and mains wiring.
Frequently Asked Questions about FC-202P2K2T6131G2829:
Q: What are the dimensions of the FC-202P2K2T6131G2829?
A: With an A3 chassis, the FC-202P2K2T6131G2829 has dimensions of 268 mm x 130 mm x 205 mm.
Q: What is the maximum trip level of the FC-202P2K2T6131G2829?
A: The FC-202P2K2T6131G2829 has a maximum trip level of 25 A.
Q: How many programmable pulse inputs does the FC-202P2K2T6131G2829 have?
A: Terminals 29 and 33 of the FC-202P2K2T6131G2829 may be used to connect a maximum of 2 programmable pulse inputs.
Q: What is the voltage range of the FC-202P2K2T6131G2829’s digital outputs?
A: The FC-202P2K2T6131G2829’s digital outputs can have a voltage level of 0 to 24 VDC.
Q: What are the characteristics of the FC-202P2K2T6131G2829’s analog output terminal?
A: Terminal 42 of the FC-202P2K2T6131G2829, which corresponds to the analog output, has an 8-bit resolution and a current range of 0/4-20 mA.