FC-202P2K2T4134H1864 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P2K2T4134H1864 is part of the VLT FC 202 AQUA Drives series and delivers a power rating of 2.2 kW or 3.0 HP. It operates on three phase power with a mains voltage range of 380 to 480 VAC and includes an RFI Class A1/B (C1) filter for electromagnetic compatibility.
Internal Product Review
The FC-202P2K2T4134H1864 is a VLT AQUA drive with a 2.2 kW power rating. Three-phase 380 to 480 VAC input gives the unit solid application flexibility for pump and fan control. RFI Class A1/B (C1) filtering is a strong advantage, making this drive an excellent fit for clean and dependable AQUA installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P2K2T4134H1864 is a variable-frequency drive produced by Danfoss as part of the VLT FC 202 AQUA Drives series. It modulates output frequency and voltage for centrifugal pumps, blowers, and related equipment so that flow matches real-time demand in water and wastewater processes. By converting fixed mains power into a regulated AC waveform, the drive can integrate with distributed control architectures and reduce energy consumption. Its soft-start capability also limits mechanical stress on valves, couplings, and other drive components during pump acceleration.
The drive is rated for 3.0 HP, which indicates the mechanical power available to the motor shaft at nominal speed. Its continuous electrical output is 2.2 kW, establishing the operating limit before thermal derating is required. A three-phase power input connects directly to industrial distribution networks, and the input range of 380 to 480 VAC supports common 400 V systems while accommodating moderate voltage variation. Conducted emissions are attenuated by the integrated RFI Class A1/B (C1) filter. This filter supports installations that must satisfy category C1 electromagnetic compatibility requirements without additional line-filter components.
Application controls include PID pump regulation, which adjusts motor speed to maintain a selected pressure, flow, or level setpoint as operating demand changes. The integrated sleep mode can stop the motor during periods of low demand and restart it when the monitored process value falls outside the selected range. A pipe-fill routine controls pump acceleration while an empty piping system fills, helping reduce pressure surges and water hammer. The drive also supports automatic energy optimization for variable-torque loads, allowing the motor voltage to follow operating conditions without unnecessary power consumption. Its mechanical layout places the cooling path and terminals within a compact enclosure suited to control-panel installations. Accessible power and control connections simplify integration with pumps, process sensors, external controllers, and standard industrial distribution equipment.