4.94 based on 222 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

FC-202P2K2T4131X7792 Danfoss

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC-202P2K2T4131X7792 is a Danfoss VLT FC 202 AQUA drive built for three-phase power on 380–480 VAC mains. A 0.97 efficiency rating and 2.2 kW power capacity make this unit a very capable choice for energy-conscious pump and fan applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202P2K2T4131X7792 is an AC variable-frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. It modulates three-phase power to control centrifugal pumps, blowers, and similar water-handling equipment in industrial and municipal automation systems. By matching motor speed to real-time flow or pressure demands, the drive can reduce unnecessary motor operation while maintaining the required process output.

This model delivers a mechanical output of 2.2 kW, which corresponds to 3.0 HP for installations that use imperial units. It operates from a three-phase mains supply of 380 to 480 VAC, and its efficiency ratio of 0.97 limits the portion of input energy lost as heat. At 400 V, its continuous apparent power is 3.9 kVA, supported by 5.0 A of input current and 5.6 A of motor-side current. Higher line voltages reduce these current levels proportionally within the supported supply range. Internal thermal paths dissipate 88 W under nominal conditions, allowing cabinet ventilation to account for the heat generated during continuous operation. Protection routines monitor line synchronization and IGBT temperature to help prevent overloads or supply imbalances from affecting torque regulation.

The drive maintains rated performance at ambient temperatures up to 50 °C, enabling installation in pump galleries or roof-mounted enclosures without derating when adequate airflow is available. A dedicated 20 A upstream fuse protects supply conductors from fault energy while preserving operation during short transient voltage dips. For motor wiring, shielded cable can extend up to 150 m, providing flexibility when the drive and motor cannot be installed near each other. Unshielded motor cable may extend up to 300 m, supporting remote submersible pumps without requiring output reactors. Three-phase conduction timing is adjusted to support torque at low motor speeds. Selectable switching patterns can also reduce audible motor noise in HVAC and water-handling applications.

Cont. Input @ 380–440 V
5.0 A
Cont. Input @ 441–480 V
4.3 A
Cont. Output @ 380–440 V
5.6 A
Cont. Output @ 441–480 V
4.8 A
Continuous Kva @ 400 V
3.9 kVA
Continuous Kva @ 460 V
3.8 kVA
Efficiency
0.97
Horse Power
3.0 HP
Mains Voltage
380 - 480 VAC
Max Ambient Temp
50 °C
Max Pre-fuse
20 A
Max Shielded Motor Cable
150 m
Max Unshielded Motor Cable
300 m
Power Loss
88 W
Power Phase
Three Phase Power
Power Rating
2.2 KW
Product Group
VLT AQUA Drive
Series Identifier
202

Frequently Asked Questions about FC-202P2K2T4131X7792:

Q: What is the continuous input current rating for Danfoss FC-202P2K2T4131X7792 at 380–440 V?

A: The continuous input current for the FC-202P2K2T4131X7792 at 380–440 V is 5.0 A.

Q: What is the continuous output current when using the FC-202P2K2T4131X7792 at 380–440 V?

A: This model delivers a continuous output of 5.6 A when operated at 380–440 V.

Q: What are the power and horsepower ratings for the FC-202P2K2T4131X7792 drive?

A: The FC-202P2K2T4131X7792 has a power rating of 2.2 kW and provides 3.0 horsepower.

Q: What is the maximum length allowed for shielded motor cables with the FC-202P2K2T4131X7792?

A: The maximum shielded motor cable length supported is 150 meters.

Q: What voltage range and phase does the FC-202P2K2T4131X7792 support?

A: This drive operates with a mains voltage range from 380 to 480 VAC on three phase power.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo