FC-202P2K2T4131F2975 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P2K2T4131F2975 is a VLT FC 202 AQUA Drives series product offering a power rating of 2.2 kW and 3.0 horsepower. It supports three phase power input from 380 to 480 VAC and delivers continuous output currents of 5.6 A at 380-440 V or 4.8 A at 441-480 V. The drive has an efficiency of 0.97 and uses an 8-bit analog output resolution.
Internal Product Review
The FC-202P2K2T4131F2975 is a Danfoss VLT FC 202 AQUA drive built for three-phase 380 - 480 VAC operation. A 2.2 kW power rating combined with 0.97 efficiency gives the unit very appealing electrical performance for continuous-duty applications. The 32 kHz maximum digital frequency output is a strong technical advantage for smooth drive control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P2K2T4131F2975 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It converts fixed three-phase power into a modulated output so centrifugal pumps and aeration blowers in water and wastewater plants can match flow to process demand. The unit belongs to the VLT AQUA Drive product group and carries the internal series identifier 202, providing control functions tailored to liquid-handling applications.
The rated output power is 2.2 kW, equivalent to 3.0 HP, enabling the inverter to run small to midsize pump motors. It accepts power from 380–480 VAC grids and reaches an efficiency of 0.97 under nominal load, limiting waste heat. Continuous apparent power is 3.9 kVA at 400 V and 3.8 kVA at 460 V. The drive can deliver up to 5.6 A of output current in the 380–440 V band, while the 441–480 V range supports an output current of 4.8 A. An 8-bit analog output provides basic process feedback to SCADA systems. The three-phase architecture and dedicated AQUA functions, such as pipe-fill control and end-of-curve detection, allow precise regulation without external PLC code.
The digital control stage issues carrier pulses at frequencies up to 32 kHz and provides a maximum sourcing capability of 40 mA for field I/O. Input current peaks at 5.0 A on 380–440 V mains and drops to 4.3 A on 441–480 V supplies. Upstream conductors are protected by a 20 A prefuse. Line-disconnect wiring can have a cross-sectional area of up to 6 mm², while motor or brake leads are limited to 4 mm². Full-load thermal dissipation is held to 88 W, reducing enclosure cooling requirements and helping the drive maintain stable operation under sustained loads.