Internal Product Review

The FC-202P2K2T4131B8903 is a Danfoss VLT FC 202 AQUA drive engineered for 380-480 VAC three-phase power. High 0.97 efficiency and a 2.2 kW power rating support stable, energy-conscious motor control in continuous service. A maximum output frequency of 590 Hz stands out as a strong capability for demanding variable-speed applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202P2K2T4131B8903 is a variable-frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It converts fixed-frequency three-phase power into a controllable output for pump and blower motors in water-treatment facilities. The adjustable output allows connected equipment to match real-time flow or pressure demands. This control can improve process accuracy and reduce energy use in industrial automation applications.

The drive operates from a 380–480 V AC mains supply and accepts three-phase power without an external transformer. With a 400 V line supply, it can deliver a continuous apparent power of 3.9 kVA, while its apparent power rating at 460 V is 3.8 kVA. Continuous output current reaches 5.6 A on 380–440 V networks and 4.8 A when the input is between 441 and 480 V. These current ratings support the selection of suitable overload protection and cable sizes for the connected motor. An efficiency of 0.97 indicates that only a small portion of the input energy is lost as heat, which supports efficient operation in water and wastewater systems.

An estimated power dissipation of 88 W must be removed through panel ventilation to help maintain acceptable component temperatures. The rated shaft output is 3.0 HP, which corresponds to 2.2 kW and supports midsize centrifugal pumps commonly used in distribution loops. For applications that require high impeller speeds, the inverter can generate output frequencies up to 590 Hz. Maximum input demand rises to 5.0 A on 380–440 V supplies and 4.3 A on 441–480 V supplies. A 20 A pre-fuse protects the upstream circuitry from excessive current. The terminals for disconnect devices accommodate conductors up to 6 mm², while the motor terminals accept conductors up to 4 mm². Shielded motor cable runs can extend as far as 150 m without exceeding the drive’s filter limits.

Cont Kva At 400 V
3.9 kVA
Cont Kva At 460 V
3.8 kVA
Cont Output Current 380-440 V
5.6 A
Cont Output Current 441-480 V
4.8 A
Efficiency
0.97
Estimated Power Loss
88 W
Horse Power
3.0 HP
Mains Voltage
380 - 480 VAC
Max Disconnect Cross-section
6 mm²
Max Input Current 380-440 V
5.0 A
Max Input Current 441-480 V
4.3 A
Max Output Frequency
590 Hz
Max Power Cable Cross-section
4 mm²
Max Shielded Motor Cable
150 m
Maximum Pre-fuse
20 A
Power Phase
Three Phase Power
Power Rating
2.2 KW
Product Group
VLT AQUA Drive
Series Identifier
202

Frequently Asked Questions about FC-202P2K2T4131B8903:

Q: What is the continuous output current for the FC-202P2K2T4131B8903 at 380-440 V?

A: The FC-202P2K2T4131B8903 provides a continuous output current of 5.6 A when operated at 380-440 V.

Q: What is the mains voltage specification for the FC-202P2K2T4131B8903?

A: This drive is rated for three-phase mains voltages ranging from 380 to 480 VAC.

Q: What is the maximum output frequency of the FC-202P2K2T4131B8903?

A: The maximum output frequency supported by the FC-202P2K2T4131B8903 is 590 Hz.

Q: What is the power rating and horsepower of the FC-202P2K2T4131B8903?

A: This model offers a power rating of 2.2 kW or 3.0 HP for connected loads.

Q: What is the estimated power loss for the FC-202P2K2T4131B8903?

A: The estimated power loss for the FC-202P2K2T4131B8903 during operation is 88 W.