FC-202P22KT6131G2906 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P22KT6131G2906 is part of the VLT FC 202 AQUA Drives series and is designed for three phase power with a power rating of 22 kW and 30 HP. It operates at a continuous output current of 34 A on 600 V and an efficiency of 0.98, with a maximum ambient temperature of 50 °C. The drive allows for maximum motor cable lengths of 150 meters shielded and 300 meters unshielded and supports a maximum installation altitude of 1000 meters without derating.
Internal Product Review
The FC-202P22KT6131G2906 is a Danfoss VLT FC 202 AQUA Drive rated for 22 kW with three-phase power input. With 0.98 efficiency and 34 A continuous output current at 600 V, the drive presents strong energy performance for demanding water and process applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P22KT6131G2906 is an AC variable-frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. The unit modulates a three-phase power supply to regulate centrifugal pumps, blowers, and other water-handling equipment in automated facilities. By adjusting motor speed instead of mechanically throttling flow, the inverter can reduce energy consumption and mechanical stress across a wide operating range. This speed-based control also allows the connected equipment to respond to changing process demands without relying on continuously restricted valves or dampers.
The inverter provides a motor output of up to 22 kW, which is approximately 30 HP, while operating from a three-phase power supply. With a 575 V supply, it draws a continuous current of 31 A, while operation at 600 V allows it to supply 34 A to the motor terminals. During permitted short overload events, the output current can rise to 37 A without exceeding the applicable thermal limits. Full-load efficiency reaches 0.98, resulting in approximately 440 W of heat that must be removed through cabinet ventilation. The control terminals provide a 40 mA digital sink for external relays. The analog reference circuit supports loads as low as 500 Ω without significant signal droop, allowing stable communication with compatible process controls.
The drive can operate continuously at ambient temperatures up to 50 °C. It maintains full output current below an elevation of 1,000 m, while operation above that level requires derating up to the maximum permitted altitude of 3,000 m. Motor leads may extend up to 150 m when shielded cable is used or up to 300 m with unshielded cable, supporting installations in which the motor is located far from the drive enclosure. Input protection can be provided by a 60 A prefuse or the gG-50 fuse size recommended by Danfoss. The drive carries an IE2 efficiency classification and provides analog and digital interfaces for connection to process controllers. These interfaces allow external systems to send speed references, monitor operating conditions, and coordinate pump operation with facility control requirements.