FC-202P22KT4131Z4319 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P22KT4131Z4319 is part of the VLT FC 202 AQUA Drives series and provides a power rating of 22 kW with a 30 horsepower output. This drive operates on three phase power with a mains voltage range of 380 to 480 VAC and a continuous output current of 40 amps at 480 V. It features 2 digital or pulse outputs, 1 programmable analog output, and a maximum ambient operating temperature of 50°C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P22KT4131Z4319 is an AC variable frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. This member of the VLT AQUA Drive product group is built for regulating centrifugal pumps, blowers, and other water-handling machinery in municipal or industrial facilities. By modulating the voltage and frequency delivered to a three-phase induction motor, the unit maintains precise flow or pressure while reducing energy consumption and mechanical stress on the drivetrain. As a stand-alone controller, it interfaces directly with plant control signals and provides local output monitoring.
The drive supports medium-power installations supplied by 380–480 VAC three-phase power. At full line voltage, it draws a continuous input current of 36 A at 480 V and can deliver 40 A at 480 V to the motor terminals. The power rating is 22 kW, which corresponds to 30 HP, while branch circuit protection is provided by a maximum pre-fuse size of 63 A. One programmable analog output is available and can drive loads up to 500 Ω. Two digital or pulse outputs source up to 40 mA each and switch at frequencies up to 32 kHz. The product carries an IE2 energy-efficiency classification and belongs to internal series identifier 202.
The drive can operate at ambient temperatures up to 50 °C and at elevations up to 1000 m without current derating. For motor cabling, the design permits up to 150 m of shielded cable or 300 m of unshielded cable, providing layout flexibility in dispersed pump stations. Continuous internal monitoring adjusts switching patterns to match load transients. This monitoring also protects the power electronics from excessive temperatures and line imbalances. The available cable lengths support installations where the motor and drive must be positioned in separate areas of a water-handling facility.